Under-utilization of capillary glucose monitoring by type 2 diabetic patients
- PMID: 16814897
- DOI: 10.1016/j.diabres.2006.05.005
Under-utilization of capillary glucose monitoring by type 2 diabetic patients
Abstract
Objectives: Postprandial glycemic excursions contribute significantly to A1C level. Furthermore, postprandial plasma glucose (PPG) is an independent risk factor for cardiovascular disease. We have evaluated the frequency of monitoring and the level of PPG in type 2 diabetic patients followed by their family physician.
Patients and methods: Canadian multicenter observational study, including 185 type 2 diabetic patients. Capillary blood glucose was measured with an Ultrasmart glucose meter (Life Scan) during a routine visit to their general practitioner. The patients also had to answer a questionnaire concerning the time since their last meal before the visit, and the frequency of postprandial monitorings defined as <or= 3h post-meal, as well as their current treatment.
Results: Twenty six percent of patients were treated with diet and exercise alone (Group 1; n=48), 58.4% with oral agents (Group 2; n=108), and 14% with insulin (Group 3; n=26); 1.6% did not know their treatment. The proportion of patients checking their PPG, at least once during the last 15 days was 16.7% (n=8) for Group 1, 37% (n=40) for Group 2 and 46.2% (n=12) for Group 3. The means (S.D.) of PPG were 8.7 mmol/L (3.5), 10.0 (3.7) and 12.7 (4.8) for Groups 1-3, respectively. Based on the Canadian Diabetes Association recommendations for PPG targets, only 36.2% had a good control (<8 mmol/L) while 41.6% had a poor control of their PPG (>10 mmol/L). A PPG >10 mmol/L was found in 18.8% (n=9), 43.5% (n=47) and 73.1% (n=19) of patients in Groups 1-3, respectively. Independent of treatment category, the mean (S.D.) PPG measured by capillary methods was above the recommended target: 10.6 mmol/L (3.7) <1-h postprandial; 10.0 mmol/L (4.2) between 1 and 2h postprandial meal; and 9.9 (3.9) 2 and 3h after meal.
Conclusion: This observational study shows that a third of the patients measured their PPG and for those who did, only a third were within the recommended target. It suggests that the patients, and probably the treating physicians, are not aware of the importance of measuring PPG. Continued medical education strategies are required to implement the recommendations for measuring and treating PPG as part of the intensive treatment of diabetes.
Similar articles
-
Effect of exenatide on 24-hour blood glucose profile compared with placebo in patients with type 2 diabetes: a randomized, double-blind, two-arm, parallel-group, placebo-controlled, 2-week study.Clin Ther. 2008 May;30(5):858-67. doi: 10.1016/j.clinthera.2008.05.004. Clin Ther. 2008. PMID: 18555933 Clinical Trial.
-
Postprandial plasma glucose excursions and cognitive functioning in aged type 2 diabetics.Neurology. 2006 Jul 25;67(2):235-40. doi: 10.1212/01.wnl.0000224760.22802.e8. Neurology. 2006. PMID: 16864814 Clinical Trial.
-
[Characteristics of glycemic excursion in different subtypes of impaired glucose intolerance].Zhonghua Yi Xue Za Zhi. 2009 Mar 17;89(10):669-72. Zhonghua Yi Xue Za Zhi. 2009. PMID: 19595059 Chinese.
-
Importance of postprandial glucose levels as a target for glycemic control in type 2 diabetes.South Med J. 2009 Jan;102(1):60-6. doi: 10.1097/SMJ.0b013e318188898e. South Med J. 2009. PMID: 19077774 Review.
-
Plasma glucose excursions in older persons with Type 2 diabetes mellitus.J Endocrinol Invest. 2005;28(11 Suppl Proceedings):105-7. J Endocrinol Invest. 2005. PMID: 16760636 Review.
Cited by
-
Use of an integrated strip-free blood glucose monitoring system increases frequency of self-monitoring and improves glycemic control: Results from the ExAct study.J Clin Transl Endocrinol. 2014 Sep 3;1(4):161-166. doi: 10.1016/j.jcte.2014.08.003. eCollection 2014 Dec. J Clin Transl Endocrinol. 2014. PMID: 29159096 Free PMC article.
-
Evaluation of a New Noninvasive Glucose Monitoring Device by Means of Standardized Meal Experiments.J Diabetes Sci Technol. 2018 Nov;12(6):1178-1183. doi: 10.1177/1932296818758769. Epub 2018 Feb 16. J Diabetes Sci Technol. 2018. PMID: 29451016 Free PMC article. Clinical Trial.
-
Use of an automated bolus calculator reduces fear of hypoglycemia and improves confidence in dosage accuracy in patients with type 1 diabetes mellitus treated with multiple daily insulin injections.J Diabetes Sci Technol. 2012 Jan 1;6(1):144-9. doi: 10.1177/193229681200600117. J Diabetes Sci Technol. 2012. PMID: 22401332 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical