Para-chlorophenol containing synthetic wastewater treatment in an activated sludge unit: effects of hydraulic residence time
- PMID: 16814923
- DOI: 10.1016/j.jenvman.2006.04.002
Para-chlorophenol containing synthetic wastewater treatment in an activated sludge unit: effects of hydraulic residence time
Abstract
Due to the toxic nature of chlorophenol compounds present in some chemical industry effluents, biological treatment of such wastewaters is usually realized with low treatment efficiencies. Para-chlorophenol (4-chlorophenol, 4-CP) containing synthetic wastewater was treated in an activated sludge unit at different hydraulic residence times (HRT) varying between 5 and 30 h while the feed COD (2500 mg l(-1)), 4-CP (500 mg l(-1)) and sludge age (SRT, 10 days) were constant. Effects of HRT variations on COD, 4-CP, toxicity removals and on settling characteristics of the sludge were investigated. Percent COD removals increased and the effluent COD concentrations decreased when HRT increased from 5 to 15 h and remained almost constant for larger HRT levels. Nearly, 91% COD and 99% 4-CP removals were obtained at HRT levels above 15 h. Because of the highly concentrated microbial population at HRT levels of above 15 h, low effluent (reactor) 4-CP concentrations and almost complete toxicity removals were obtained. High biomass concentrations obtained at HRT levels above 15 h were due to low 4-CP contents in the aeration tank yielding negligible inhibition effects and low maintenance requirements. The sludge volume index (SVI) decreased with increasing HRT up to 15 h due to high biomass concentrations at high HRT levels resulting in well settling sludge with low SVI values. Hydraulic residence times above 15 h resulted in more than 90% COD and complete 4-CP and toxicity removals along with well settling sludge.
Similar articles
-
COD, para-chlorophenol and toxicity removal from para-chlorophenol containing synthetic wastewater in an activated sludge unit.J Hazard Mater. 2006 May 20;132(2-3):226-31. doi: 10.1016/j.jhazmat.2005.09.040. Epub 2005 Oct 27. J Hazard Mater. 2006. PMID: 16257114
-
Biological treatment of synthetic wastewater containing 2,4 dichlorophenol (DCP) in an activated sludge unit.J Environ Manage. 2005 Aug;76(3):191-6. doi: 10.1016/j.jenvman.2005.02.007. J Environ Manage. 2005. PMID: 15922505
-
Performance of a hybrid-loop bioreactor system in biological treatment of 2,4,6-tri-chlorophenol containing synthetic wastewater: effects of hydraulic residence time.J Hazard Mater. 2007 Jun 1;144(1-2):86-92. doi: 10.1016/j.jhazmat.2006.09.084. Epub 2006 Oct 1. J Hazard Mater. 2007. PMID: 17070650
-
Biological processes for treatment of landfill leachate.J Environ Monit. 2010 Nov;12(11):2032-47. doi: 10.1039/c0em00076k. Epub 2010 Sep 17. J Environ Monit. 2010. PMID: 20848046 Review.
-
Assessing wastewater toxicity to activated sludge: recent research and developments.Environ Int. 2004 Oct;30(8):1151-64. doi: 10.1016/j.envint.2004.06.003. Environ Int. 2004. PMID: 15337358 Review.
Cited by
-
Biodegradation of 4-chlorophenol in an airlift inner loop bioreactor with mixed consortium: effect of HRT, loading rate and biogenic substrate.3 Biotech. 2016 Dec;6(2):117. doi: 10.1007/s13205-016-0435-5. Epub 2016 Jun 2. 3 Biotech. 2016. PMID: 28330191 Free PMC article.
-
In-sewer iron dosing enhances bioenergy recovery in downstream sewage sludge anaerobic digestion: The impact of iron salt types and thermal hydrolysis pretreatment.Water Res X. 2024 Oct 29;25:100273. doi: 10.1016/j.wroa.2024.100273. eCollection 2024 Dec 1. Water Res X. 2024. PMID: 39559552 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous