Porous coated motion cervical disc replacement: a biomechanical, histomorphometric, and biologic wear analysis in a caprine model
- PMID: 16816760
- DOI: 10.1097/01.brs.0000224537.79234.21
Porous coated motion cervical disc replacement: a biomechanical, histomorphometric, and biologic wear analysis in a caprine model
Abstract
Study design: The biomechanical, histopathologic, and histomorphometric characteristics of cervical disc replacement were assessed in a caprine animal model.
Objective: To investigate the biomechanical, porous ingrowth, and histopathologic characteristics of the Porous Coated Motion (PCM) Cervical Disc replacement (Cervitech, Inc., Rockaway, NJ).
Summary of background data: As an alternative to anterior cervical interbody arthrodesis, an artificial cervical disc serves to replace the symptomatic degenerated disc, restore the functional biomechanical properties of the motion segment, and preserve neurologic function.
Methods: There were 12 mature Nubian goats divided into 2 groups based on postoperative survival periods of 6 (n = 6) and 12 months (n = 6). Using an anterior surgical approach, a complete discectomy was performed at the C3-C4, followed by implantation of the PCM device. Functional outcomes of the disc prosthesis were based on computerized tomography (CT), multidirectional flexibility testing, undecalcified histology, histomorphometric, and immunocytochemical analyses.
Results: There was no evidence of prosthesis loosening, or neurologic or vascular complications. CT showed the ability to image and assess the cervical spinal canal for the presence of compressive pathology in the area of the CoCrMo prosthesis. Multidirectional flexibility testing under axial rotation and lateral bending indicated no differences in the full range of intervertebral motion between the disc prosthesis and nonoperative controls (P > 0.05). Based on immunohistochemical and histologic analysis, there was no evidence of particulate debris, cytokines, or cellular apoptosis within the local or systemic tissues. Moreover, review of the spinal cord at the operative levels indicated no evidence of cord lesions, inflammatory reaction, wear particles, or significant pathologic changes in any treatment. Histomorphometric analysis at the metal-bone interface indicated the mean trabecular ingrowth of 40.5% +/- 24.4% and 58.65% +/- 28.04% for the 6 and 12-month treatments, respectively.
Conclusion: To our knowledge, this serves as the first in vivo time-course study investigating the use of the PCM device for cervical arthroplasty. All 12 animals undergoing cervical disc replacement had no evidence of implant loosening, subluxation, or inflammatory reactions. PCM cervical arthroplasty permits unobstructed visualization of the spinal canal based on CT imaging. Segmental intervertebral motion was preserved under axial rotation and lateral bending loading conditions, while at the same time permitting porous osseointegration at the prosthesis-bone interface. Based on histopathologic review of all local and systemic tissues, there was no evidence of particulate wear debris, cytokines, cellular apoptosis, or significant pathologic changes in any treatment.
Similar articles
-
Cervical disc replacement-porous coated motion prosthesis: a comparative biomechanical analysis showing the key role of the posterior longitudinal ligament.Spine (Phila Pa 1976). 2003 Oct 15;28(20):S176-85. doi: 10.1097/01.BRS.0000092219.28382.0C. Spine (Phila Pa 1976). 2003. PMID: 14560189
-
Basic scientific considerations in total disc arthroplasty.Spine J. 2004 Nov-Dec;4(6 Suppl):219S-230S. doi: 10.1016/j.spinee.2004.07.015. Spine J. 2004. PMID: 15541670 Review.
-
Total disc replacement arthroplasty using the AcroFlex lumbar disc: a non-human primate model.Eur Spine J. 2002 Oct;11 Suppl 2(Suppl 2):S115-23. doi: 10.1007/s00586-002-0481-z. Epub 2002 Aug 20. Eur Spine J. 2002. PMID: 12384732 Free PMC article.
-
Biomechanical comparison of single- and two-level cervical arthroplasty versus arthrodesis: effect on adjacent-level spinal kinematics.Spine J. 2010 Apr;10(4):341-9. doi: 10.1016/j.spinee.2010.01.006. Spine J. 2010. PMID: 20362252
-
Delayed hyper-reactivity to metal ions after cervical disc arthroplasty: a case report and literature review.Spine (Phila Pa 1976). 2009 Apr 1;34(7):E262-5. doi: 10.1097/BRS.0b013e318195dd60. Spine (Phila Pa 1976). 2009. PMID: 19333091 Review.
Cited by
-
A comparison of the shock-absorbing properties of cervical disc prosthesis bearing materials.SAS J. 2011 Jun 1;5(2):48-54. doi: 10.1016/j.esas.2011.01.002. eCollection 2011. SAS J. 2011. PMID: 25802668 Free PMC article.
-
Range of motion of the mid-cervical spine: human versus goat.J Orthop Surg Res. 2023 Jun 8;18(1):416. doi: 10.1186/s13018-023-03896-1. J Orthop Surg Res. 2023. PMID: 37291606 Free PMC article.
-
Parathyroid hormone enhances gap healing and osseointegration in orthopedic porous coated titanium implants: a correlative micro-computed tomographic, histomorphometric and biomechanical analysis.BMC Musculoskelet Disord. 2022 Jan 3;23(1):17. doi: 10.1186/s12891-021-04917-y. BMC Musculoskelet Disord. 2022. PMID: 34980060 Free PMC article.
-
A systematic review of cervical artificial disc replacement wear characteristics and durability.Evid Based Spine Care J. 2012 Feb;3(S1):31-8. doi: 10.1055/s-0031-1298606. Evid Based Spine Care J. 2012. PMID: 23236311 Free PMC article.
-
In-vivo study of osseointegration in Prestige LP cervical disc prosthesis.BMC Musculoskelet Disord. 2018 Feb 7;19(1):42. doi: 10.1186/s12891-018-1957-2. BMC Musculoskelet Disord. 2018. PMID: 29415694 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous