Blood flow affects light transmission but its impact on NIRS remains unclear
- PMID: 16822683
- DOI: 10.1016/j.neuroimage.2006.05.041
Blood flow affects light transmission but its impact on NIRS remains unclear
Abstract
While most investigators that use near infrared spectroscopy (NIRS)-based techniques do not believe that changes in light transmission are exclusively attributable to hemoglobin changes, most only consider the various hemoglobin moieties when decomposing the source signal. In their commentary, Tomita and colleagues challenge this assumption and speculate that the majority of the NIRS signal is due to flow effects rather than changes in hemoglobin. While the authors present convincing preliminary evidence that flow can affect light transmission, the authors stop short of providing conclusive evidence that the flow effect is indeed significant when using spectroscopic techniques. Nevertheless, the authors raise sufficient concern regarding the potential contribution of the "flow-effect" to warrant further investigations.
Comment on
-
Contribution of the flow effect caused by shear-dependent RBC aggregation to NIR spectroscopic signals.Neuroimage. 2006 Oct 15;33(1):1-10. doi: 10.1016/j.neuroimage.2006.05.042. Epub 2006 Jul 31. Neuroimage. 2006. PMID: 16877009
Similar articles
-
Contribution of the flow effect caused by shear-dependent RBC aggregation to NIR spectroscopic signals.Neuroimage. 2006 Oct 15;33(1):1-10. doi: 10.1016/j.neuroimage.2006.05.042. Epub 2006 Jul 31. Neuroimage. 2006. PMID: 16877009
-
Flow effect impacts NIRS, jeopardizing quantification of tissue hemoglobin.Neuroimage. 2006 Oct 15;33(1):13-6. doi: 10.1016/j.neuroimage.2006.06.046. Epub 2006 Aug 17. Neuroimage. 2006. PMID: 16919482
-
Relevance of depth resolution for cerebral blood flow monitoring by near-infrared spectroscopic bolus tracking during cardiopulmonary bypass.J Thorac Cardiovasc Surg. 2006 Nov;132(5):1172-8. doi: 10.1016/j.jtcvs.2006.05.065. J Thorac Cardiovasc Surg. 2006. PMID: 17059940
-
Near infrared spectroscopy (NIRS) in children.Semin Cardiothorac Vasc Anesth. 2008 Mar;12(1):70-9. doi: 10.1177/1089253208316444. Epub 2008 Apr 2. Semin Cardiothorac Vasc Anesth. 2008. PMID: 18387980 Review.
-
The value of near-infrared spectroscopy measured cerebral oximetry during carotid endarterectomy in perioperative stroke prevention. A review.Eur J Vasc Endovasc Surg. 2009 Nov;38(5):539-45. doi: 10.1016/j.ejvs.2009.07.008. Epub 2009 Aug 7. Eur J Vasc Endovasc Surg. 2009. PMID: 19665397 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources