MR image reconstruction of sparsely sampled 3D k-space data by projection-onto-convex sets
- PMID: 16824971
- DOI: 10.1016/j.mri.2005.12.028
MR image reconstruction of sparsely sampled 3D k-space data by projection-onto-convex sets
Abstract
In many rapid three-dimensional (3D) magnetic resonance (MR) imaging applications, such as when following a contrast bolus in the vasculature using a moving table technique, the desired k-space data cannot be fully acquired due to scan time limitations. One solution to this problem is to sparsely sample the data space. Typically, the central zone of k-space is fully sampled, but the peripheral zone is partially sampled. We have experimentally evaluated the application of the projection-onto-convex sets (POCS) and zero-filling (ZF) algorithms for the reconstruction of sparsely sampled 3D k-space data. Both a subjective assessment (by direct image visualization) and an objective analysis [using standard image quality parameters such as global and local performance error and signal-to-noise ratio (SNR)] were employed. Compared to ZF, the POCS algorithm was found to be a powerful and robust method for reconstructing images from sparsely sampled 3D k-space data, a practical strategy for greatly reducing scan time. The POCS algorithm reconstructed a faithful representation of the true image and improved image quality with regard to global and local performance error, with respect to the ZF images. SNR, however, was superior to ZF only when more than 20% of the data were sparsely sampled. POCS-based methods show potential for reconstructing fast 3D MR images obtained by sparse sampling.
Similar articles
-
Consecutive projections onto convex sets.Phys Med Biol. 2002 Mar 21;47(6):N61-6. Phys Med Biol. 2002. PMID: 11936184
-
[Fast 3D surface rendering for CT or MR image on a personal computer].Space Med Med Eng (Beijing). 2002 Aug;15(4):296-9. Space Med Med Eng (Beijing). 2002. PMID: 12425338 Chinese.
-
Rapid passive MR catheter visualization for endovascular therapy using nonsymmetric truncated k-space sampling strategies.Magn Reson Imaging. 2008 Apr;26(3):293-303. doi: 10.1016/j.mri.2007.08.002. Epub 2008 Feb 20. Magn Reson Imaging. 2008. PMID: 18068928
-
Undersampled radial MR acquisition and highly constrained back projection (HYPR) reconstruction: potential medical imaging applications in the post-Nyquist era.J Magn Reson Imaging. 2009 Mar;29(3):501-16. doi: 10.1002/jmri.21683. J Magn Reson Imaging. 2009. PMID: 19243031 Review.
-
3D contrast-enhanced MR angiography.J Magn Reson Imaging. 2007 Jan;25(1):13-25. doi: 10.1002/jmri.20767. J Magn Reson Imaging. 2007. PMID: 17154188 Review.
Cited by
-
Efficacy of the projection onto convex sets (POCS) algorithm at Gd-EOB-DTPA-enhanced hepatobiliary-phase hepatic MRI.Springerplus. 2016 Aug 9;5(1):1311. doi: 10.1186/s40064-016-2968-9. eCollection 2016. Springerplus. 2016. PMID: 27547685 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical