Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Sep;16(5):659-70.
doi: 10.1007/s10895-006-0104-x. Epub 2006 Jul 7.

The use of poly(sodium N-undecanoyl-L-leucylvalinate), poly(sodium N-undecanoyl-L-leucinate) and poly(sodium N-undecanoyl-L-valinate) surfactants as chiral selectors for determination of enantiomeric composition of samples by multivariate regression modeling of fluorescence spectral data

Affiliations

The use of poly(sodium N-undecanoyl-L-leucylvalinate), poly(sodium N-undecanoyl-L-leucinate) and poly(sodium N-undecanoyl-L-valinate) surfactants as chiral selectors for determination of enantiomeric composition of samples by multivariate regression modeling of fluorescence spectral data

Sayo O Fakayode et al. J Fluoresc. 2006 Sep.

Abstract

Steady-state fluorescence spectroscopy was employed to investigate the use of chiral polymeric surfactants as chiral selectors in chiral analysis by multivariate regression modeling of spectral data. Partial-least-squares regression modeling (PLS-1) was used to correlate changes in the fluorescence spectral data of 1,1'-bi-2-naphthol (BOH), 1,1'-binaphthyl-2,2'-diamine (BNA), or 2,2,2-trifluoroanthrylethanol (TFA) in the presence of poly(sodium N-undecanoyl-L-leucylvalinate), poly(sodium N-undecanoyl-L-leucinate) or poly(sodium N-undecanoyl-L-valinate) as the enantiomeric composition of the chiral analytes was varied. The regression models produced from the spectral data were validated by determining the enantiomeric composition of independently prepared test solutions. The ability of the model to correctly predict the enantiomeric composition of future samples was evaluated using the root-mean-square percent-relative error (RMS%RE) of prediction. In terms of RMS%RE, the ability of the model to accurately predict the enantiomeric composition of future samples was dependent on the chiral analyte, the polymeric surfactant used, and the surfactant medium, and ranged between 1.57 and 6.10%. Chiral analyte concentrations as low as 5 x 10(-6) M were found to give regression models with good predictability.

PubMed Disclaimer

References

    1. Electrophoresis. 1999 Sep;20(12):2458-61 - PubMed
    1. Talanta. 2005 Feb 28;65(4):838-45 - PubMed
    1. Analyst. 2005 Feb;130(2):233-41 - PubMed
    1. J Chromatogr A. 1996 Jan 5;719(1):3-13 - PubMed
    1. J Am Chem Soc. 2003 Feb 19;125(7):1690-1 - PubMed

Publication types

MeSH terms

LinkOut - more resources