Comparative assessment of statistical brain MR image segmentation algorithms and their impact on partial volume correction in PET
- PMID: 16828315
- DOI: 10.1016/j.neuroimage.2006.05.031
Comparative assessment of statistical brain MR image segmentation algorithms and their impact on partial volume correction in PET
Abstract
Magnetic resonance imaging (MRI)-guided partial volume effect correction (PVC) in brain positron emission tomography (PET) is now a well-established approach to compensate the large bias in the estimate of regional radioactivity concentration, especially for small structures. The accuracy of the algorithms developed so far is, however, largely dependent on the performance of segmentation methods partitioning MRI brain data into its main classes, namely gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF). A comparative evaluation of three brain MRI segmentation algorithms using simulated and clinical brain MR data was performed, and subsequently their impact on PVC in 18F-FDG and 18F-DOPA brain PET imaging was assessed. Two algorithms, the first is bundled in the Statistical Parametric Mapping (SPM2) package while the other is the Expectation Maximization Segmentation (EMS) algorithm, incorporate a priori probability images derived from MR images of a large number of subjects. The third, here referred to as the HBSA algorithm, is a histogram-based segmentation algorithm incorporating an Expectation Maximization approach to model a four-Gaussian mixture for both global and local histograms. Simulated under different combinations of noise and intensity non-uniformity, MR brain phantoms with known true volumes for the different brain classes were generated. The algorithms' performance was checked by calculating the kappa index assessing similarities with the "ground truth" as well as multiclass type I and type II errors including misclassification rates. The impact of image segmentation algorithms on PVC was then quantified using clinical data. The segmented tissues of patients' brain MRI were given as input to the region of interest (RoI)-based geometric transfer matrix (GTM) PVC algorithm, and quantitative comparisons were made. The results of digital MRI phantom studies suggest that the use of HBSA produces the best performance for WM classification. For GM classification, it is suggested to use the EMS. Segmentation performed on clinical MRI data show quite substantial differences, especially when lesions are present. For the particular case of PVC, SPM2 and EMS algorithms show very similar results and may be used interchangeably. The use of HBSA is not recommended for PVC. The partial volume corrected activities in some regions of the brain show quite large relative differences when performing paired analysis on 2 algorithms, implying a careful choice of the segmentation algorithm for GTM-based PVC.
Similar articles
-
Anatomically guided voxel-based partial volume effect correction in brain PET: impact of MRI segmentation.Comput Med Imaging Graph. 2012 Dec;36(8):610-9. doi: 10.1016/j.compmedimag.2012.09.001. Epub 2012 Oct 6. Comput Med Imaging Graph. 2012. PMID: 23046730
-
Simulation-based partial volume correction for dopaminergic PET imaging: Impact of segmentation accuracy.Z Med Phys. 2015 Sep;25(3):230-42. doi: 10.1016/j.zemedi.2014.08.001. Epub 2014 Sep 22. Z Med Phys. 2015. PMID: 25172832
-
Partial volume correction for in vivo (23)Na-MRI data of the human brain.Neuroimage. 2015 May 15;112:353-363. doi: 10.1016/j.neuroimage.2015.03.025. Epub 2015 Mar 20. Neuroimage. 2015. PMID: 25797831
-
MR Imaging-Guided Partial Volume Correction of PET Data in PET/MR Imaging.PET Clin. 2016 Apr;11(2):161-77. doi: 10.1016/j.cpet.2015.09.002. Epub 2015 Nov 27. PET Clin. 2016. PMID: 26952729 Review.
-
A New Optimized Thresholding Method Using Ant Colony Algorithm for MR Brain Image Segmentation.J Digit Imaging. 2019 Feb;32(1):162-174. doi: 10.1007/s10278-018-0111-x. J Digit Imaging. 2019. PMID: 30091112 Free PMC article. Review.
Cited by
-
Multimodal Discrimination of Alzheimer's Disease Based on Regional Cortical Atrophy and Hypometabolism.PLoS One. 2015 Jun 10;10(6):e0129250. doi: 10.1371/journal.pone.0129250. eCollection 2015. PLoS One. 2015. PMID: 26061669 Free PMC article.
-
Automated medical image segmentation techniques.J Med Phys. 2010 Jan;35(1):3-14. doi: 10.4103/0971-6203.58777. J Med Phys. 2010. PMID: 20177565 Free PMC article.
-
Partial-volume effect correction in positron emission tomography brain scan image using super-resolution image reconstruction.Br J Radiol. 2015 Feb;88(1046):20140119. doi: 10.1259/bjr.20140119. Epub 2014 Dec 10. Br J Radiol. 2015. PMID: 25492553 Free PMC article.
-
Evaluation of a method for projection-based tissue-activity estimation within small volumes of interest.Phys Med Biol. 2012 Feb 7;57(3):685-701. doi: 10.1088/0031-9155/57/3/685. Epub 2012 Jan 13. Phys Med Biol. 2012. PMID: 22241591 Free PMC article.
-
PET/MRI: a frontier in era of complementary hybrid imaging.Eur J Hybrid Imaging. 2018;2(1):12. doi: 10.1186/s41824-018-0030-6. Epub 2018 Jun 25. Eur J Hybrid Imaging. 2018. PMID: 29998214 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical