Combined simulated annealing and Shinnar-Le Roux pulse design of slice-multiplexed RF pulses for multi-slice imaging
- PMID: 16828567
- DOI: 10.1016/j.jmr.2006.06.019
Combined simulated annealing and Shinnar-Le Roux pulse design of slice-multiplexed RF pulses for multi-slice imaging
Abstract
Slice-multiplexed RF pulses have recently been introduced for simultaneous multi-slice imaging. Their novel aspect is that each slice is given a different linear phase profile, and hence a different slice-rephasing requirement, by the pulse. During readout, extra slice gradients are applied such that when one slice is rephased, the others are dephased to prevent aliasing. In this paper, an improved method of designing slice-multiplexed RF pulses is presented: component pulses which are optimized with simulated annealing for a specific rephasing are combined using Shinnar-Le Roux methods. In this way, non-linearities at higher flip angles are taken into account and more slices can be excited. Bloch simulations show the phase and amplitude profile of component pulses are faithfully preserved in the multiplexed pulse. Three- and four-slice multiplex pulses are demonstrated in gradient- and spin-echo in-vivo imaging.
Similar articles
-
Chebyshev series for designing RF pulses employing an optimal control approach.IEEE Trans Med Imaging. 2004 Nov;23(11):1445-52. doi: 10.1109/TMI.2004.835602. IEEE Trans Med Imaging. 2004. PMID: 15554131
-
Simultaneous multislice imaging with slice-multiplexed RF pulses.Magn Reson Med. 2005 Oct;54(4):755-60. doi: 10.1002/mrm.20643. Magn Reson Med. 2005. PMID: 16155891
-
General parameter relations for the Shinnar-Le Roux pulse design algorithm.J Magn Reson. 2007 Jun;186(2):252-8. doi: 10.1016/j.jmr.2007.03.010. Epub 2007 Mar 19. J Magn Reson. 2007. PMID: 17408999
-
Principles of MR image formation and reconstruction.Magn Reson Imaging Clin N Am. 1999 Nov;7(4):629-59. Magn Reson Imaging Clin N Am. 1999. PMID: 10631672 Review.
-
Basic principles of magnetic resonance imaging.Neurosurg Clin N Am. 2005 Jan;16(1):1-64. doi: 10.1016/j.nec.2004.08.017. Neurosurg Clin N Am. 2005. PMID: 15561528 Review.
Cited by
-
Root-flipped multiband refocusing pulses.Magn Reson Med. 2016 Jan;75(1):227-37. doi: 10.1002/mrm.25629. Epub 2015 Feb 22. Magn Reson Med. 2016. PMID: 25704154 Free PMC article.
-
Wavelet Domain Radiofrequency Pulse Design Applied to Magnetic Resonance Imaging.PLoS One. 2015 Oct 30;10(10):e0141151. doi: 10.1371/journal.pone.0141151. eCollection 2015. PLoS One. 2015. PMID: 26517262 Free PMC article.
-
Two-axis acceleration of functional connectivity magnetic resonance imaging by parallel excitation of phase-tagged slices and half k-space acceleration.Brain Connect. 2011;1(1):81-90. doi: 10.1089/brain.2011.0004. Brain Connect. 2011. PMID: 22432957 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical