Consequences of under- and over-humidification
- PMID: 16828692
- DOI: 10.1016/j.rcc.2006.03.010
Consequences of under- and over-humidification
Abstract
Respiratory mucosal and lung structures and functions may be severely impaired in mechanically ventilated patients when delivered gases are not adequately conditioned. Although under- and over-humidification of respiratory gases have not been defined clearly, a safe range of temperature and humidity may be suggested. During mechanical ventilation, gas entering the trachea should reach at least physiologic conditions (32 degrees C-34 degrees C and 100%relative humidity) to keep the ISB at its normal location. Clinicians must keep in mind that relative humidity is more important than absolute humidity: the warmer the gas, the higher the risk of tracheal mucosa dehydration and proximal airway obstruction. Practical assessment of the adequacy of the humidification system in use is not easy. The consistency (thin, moderate, or thick) of the patient's sputum should be evaluated regularly [47]. Full saturation of inspiratory gases is likely when water condensation is observed in the flex tube [91,92]. Nevertheless, no clinical parameter is accurate enough to detect all the effects of inadequate conditioning [45]. When mechanical ventilation is extended beyond several days, adequate conditioning of respiratory gases becomes increasingly crucial to prevent retention of secretions and to maximize mucociliary function; a requirement that respiratory gases reach at least physiologic conditions is appropriate.
Similar articles
-
The effects of excessive humidity.Respir Care Clin N Am. 1998 Jun;4(2):215-28. Respir Care Clin N Am. 1998. PMID: 9648183 Review.
-
Devices used to humidify respired gases.Respir Care Clin N Am. 2006 Jun;12(2):165-82. doi: 10.1016/j.rcc.2006.03.012. Respir Care Clin N Am. 2006. PMID: 16828689 Review.
-
Humidification of respired gases in neonates and infants.Respir Care Clin N Am. 2006 Jun;12(2):321-36. doi: 10.1016/j.rcc.2006.03.002. Respir Care Clin N Am. 2006. PMID: 16828698 Review.
-
[Artificial humidification of inspired gas--status of knowledge and technique].Anaesthesiol Reanim. 1997;22(6):153-8. Anaesthesiol Reanim. 1997. PMID: 9487786 Review. German.
-
Secretion management in the mechanically ventilated patient.Respir Care. 2007 Oct;52(10):1328-42; discussion 1342-7. Respir Care. 2007. PMID: 17894902 Review.
Cited by
-
Humidification during mechanical ventilation in the adult patient.Biomed Res Int. 2014;2014:715434. doi: 10.1155/2014/715434. Epub 2014 Jun 25. Biomed Res Int. 2014. PMID: 25089275 Free PMC article. Review.
-
Nasal high flow treatment in preterm infants.Matern Health Neonatol Perinatol. 2017 Sep 6;3:15. doi: 10.1186/s40748-017-0056-y. eCollection 2017. Matern Health Neonatol Perinatol. 2017. PMID: 28904810 Free PMC article. Review.
-
Evaluation of an active humidification system for inspired gas.Clin Exp Otorhinolaryngol. 2015 Mar;8(1):69-75. doi: 10.3342/ceo.2015.8.1.69. Epub 2015 Feb 3. Clin Exp Otorhinolaryngol. 2015. PMID: 25729499 Free PMC article.
-
A Novel Scale to Assess Humidification during Noninvasive Ventilation: A Prospective Observational Study.Can Respir J. 2023 Dec 28;2023:9958707. doi: 10.1155/2023/9958707. eCollection 2023. Can Respir J. 2023. PMID: 38179551 Free PMC article.
-
Airway gas temperature within endotracheal tube can be monitored using rapid response thermometer.Sci Rep. 2021 May 5;11(1):9537. doi: 10.1038/s41598-021-88787-3. Sci Rep. 2021. PMID: 33953212 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources