Humidification of respired gases in neonates and infants
- PMID: 16828698
- DOI: 10.1016/j.rcc.2006.03.002
Humidification of respired gases in neonates and infants
Abstract
Which temperature and humidity is optimal and can be recommended to the clinician? Some authors advocate the delivery of gas at body temperature and 100% relative humidity, which is equivalent to a water content of 44 mg/L [5,88,89]. They argue that energy neutrality is the best indicator of optimum humidity and that the intubated airway cannot be equated with the natural airway. Water loss as well as temperature and humidity gradients along the airway are necessary for mucociliary clearance and maintenance of the liquid layer of the airway epithelium, however [3]. Theoretical considerations and long-lasting experience in clinical practice support a setting that mirrors physiologic conditions even in the intubated airway. Thus, saturated gas at a temperature of 330 degrees to 35 degrees C should be delivered to the airway threshold of ventilated neonates and infants. Heated humidifiers and some HMEs can comply with these conditions. With active humidification (primarily the condensation of water) over humidification or possible malfunctions must be kept in mind. The neonatologist must consider increase in deadspace, water-retention capability, leak around the tracheal tube, and the slight increase in airway resistance when using HMEs. HMEs should not be used during weaning from ventilatory support in babies who have a body weight less than 2500 g.
Similar articles
-
Devices used to humidify respired gases.Respir Care Clin N Am. 2006 Jun;12(2):165-82. doi: 10.1016/j.rcc.2006.03.012. Respir Care Clin N Am. 2006. PMID: 16828689 Review.
-
The effects of excessive humidity.Respir Care Clin N Am. 1998 Jun;4(2):215-28. Respir Care Clin N Am. 1998. PMID: 9648183 Review.
-
Consequences of under- and over-humidification.Respir Care Clin N Am. 2006 Jun;12(2):233-52. doi: 10.1016/j.rcc.2006.03.010. Respir Care Clin N Am. 2006. PMID: 16828692 Review.
-
Passive or active inspired gas humidification increases thermal steady-state temperatures in anesthetized infants.Anesth Analg. 1989 Dec;69(6):783-7. Anesth Analg. 1989. PMID: 2589661 Clinical Trial.
-
Humidification during anesthesia.Respir Care Clin N Am. 1998 Jun;4(2):281-99. Respir Care Clin N Am. 1998. PMID: 9648187 Review.
Cited by
-
Noninvasive Respiratory Support in Neonates: A Review of Current Evidence and Practices.Indian J Pediatr. 2021 Jul;88(7):670-678. doi: 10.1007/s12098-021-03755-z. Epub 2021 Jun 1. Indian J Pediatr. 2021. PMID: 34075532 Free PMC article. Review.
-
Heat and Moisture Exchangers and Humidification Efficacy in Pediatrics: Effects of Ventilator Settings and ETT Leakage.Crit Care Res Pract. 2012;2012:585280. doi: 10.1155/2012/585280. Epub 2012 Aug 1. Crit Care Res Pract. 2012. PMID: 22900156 Free PMC article. No abstract available.
-
Heat and moisture exchangers versus heated humidifiers for mechanically ventilated adults and children.Cochrane Database Syst Rev. 2017 Sep 14;9(9):CD004711. doi: 10.1002/14651858.CD004711.pub3. Cochrane Database Syst Rev. 2017. PMID: 28905374 Free PMC article.
-
Comment on "humidification with high-flow nasal cannula and airway epithelial cells: caution, still learning from an extremely complex environment".Pulm Med. 2012;2012:368713. doi: 10.1155/2012/368713. Epub 2012 Dec 24. Pulm Med. 2012. PMID: 23320164 Free PMC article. No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources