The application of LiF:Mg,Cu,P to large scale personnel dosimetry: current status and future directions
- PMID: 16835277
- DOI: 10.1093/rpd/nci692
The application of LiF:Mg,Cu,P to large scale personnel dosimetry: current status and future directions
Abstract
LiF:Mg,Cu,P is starting to replace LiF:Mg,Ti in a variety of personnel dosimetry applications. LiF:Mg,Cu,P has superior characteristics as compared to LiF:Mg,Ti including, higher sensitivity, improved energy response for photons, lack of supralinearity and insignificant fading. The use of LiF:Mg,Cu,P in large scale dosimetry programs is of particular interest due to the extreme sensitivity of this material to the maximum readout temperature, and the variety of different dosimetry aspects and details that must be considered for a successful implementation in routine dosimetry. Here we discuss and explain the various aspects of large scale LiF:Mg,Cu,P based dosimetry programs including the properties of the TL material, new generation of TLD readers, calibration methodologies, a new generation of dose calculation algorithms based on the use of artificial neural networks and the overall uncertainty of the dose measurement. The United States Navy (USN) will be the first US dosimetry processor who will use this new material for routine applications. Until June 2002, the Navy used two types of thermoluminescent materials for personnel dosimetry, CaF2:Mn and LiF:Mg,Ti. A program to upgrade the system and to implement LiF:Mg,Cu,P, started in the mid 1990s and was recently concluded. In 2002, the new system replaced the LiF:Mg,Ti and is scheduled to start replacing the CaF2:Mn system in 2006. A pilot study to determine the dosimetric performance of the new LiF:Mg,Cu,P based dosimetry system was recently completed, and the results show the new system to be as good or better than the current system in all areas tested. As a result, LiF:Mg,Cu,P is scheduled to become the primary personnel dosimeter for the entire US Navy in 2006.
Similar articles
-
Long-term fade study of the DT-702 LiF: Mg,Cu,P TLD.Radiat Prot Dosimetry. 2008;131(3):279-86. doi: 10.1093/rpd/ncn182. Epub 2008 Jul 11. Radiat Prot Dosimetry. 2008. PMID: 18621919
-
Determination of LiF:Mg,Ti and LiF:Mg,Cu,P TL efficiency for X-rays and their application to Monte Carlo simulations of dosemeter response.Radiat Prot Dosimetry. 2006;119(1-4):483-6. doi: 10.1093/rpd/ncj001. Epub 2006 Jul 5. Radiat Prot Dosimetry. 2006. PMID: 16822775
-
LiF:Mg,Cu,P glow curve shape dependence on heating rate.Radiat Prot Dosimetry. 2006;119(1-4):184-90. doi: 10.1093/rpd/nci529. Epub 2006 Mar 31. Radiat Prot Dosimetry. 2006. PMID: 16581930
-
The effects of ionisation density on the thermoluminescence response (efficiency) of LiF:Mg,Ti and LiF:Mg,Cu,P.Radiat Prot Dosimetry. 2004;109(4):331-48. doi: 10.1093/rpd/nch310. Radiat Prot Dosimetry. 2004. PMID: 15273352 Review.
-
Thermoluminescence dosimetry and its applications in medicine--Part 1: Physics, materials and equipment.Australas Phys Eng Sci Med. 1994 Dec;17(4):175-99. Australas Phys Eng Sci Med. 1994. PMID: 7872900 Review.
Cited by
-
Can computer-assisted surgery reduce the effective dose for spinal fusion and sacroiliac screw insertion?Clin Orthop Relat Res. 2010 Sep;468(9):2419-29. doi: 10.1007/s11999-010-1393-6. Epub 2010 Jun 3. Clin Orthop Relat Res. 2010. PMID: 20521129 Free PMC article.
-
Shorter exposures to harder X-rays trigger early apoptotic events in Xenopus laevis embryos.PLoS One. 2010 Jan 29;5(1):e8970. doi: 10.1371/journal.pone.0008970. PLoS One. 2010. PMID: 20126466 Free PMC article.
-
Modification of shirt buttons for retrospective radiation dosimetry after a radiological event.Health Phys. 2011 May;100(5):542-7. doi: 10.1097/HP.0b013e31820153d4. Health Phys. 2011. PMID: 21451325 Free PMC article.
-
Effect of redox reactions on the thermoluminescence characteristics of Cu-doped NaLi2PO4 phosphors.RSC Adv. 2023 Jul 6;13(29):20298-20313. doi: 10.1039/d3ra02498a. eCollection 2023 Jun 29. RSC Adv. 2023. PMID: 37425624 Free PMC article.
-
Effect of short-term sensitivity loss in LiF:Mg,Cu,P thermoluminescent dosemeter and its implications on personnel dosimetry operations.Radiat Prot Dosimetry. 2016 Feb;168(2):204-11. doi: 10.1093/rpd/ncv017. Epub 2015 Mar 11. Radiat Prot Dosimetry. 2016. PMID: 25767182 Free PMC article.