Age, size, and lead factors alone do not predict venous obstruction in children and young adults with transvenous lead systems
- PMID: 16836673
- DOI: 10.1111/j.1540-8167.2006.00489.x
Age, size, and lead factors alone do not predict venous obstruction in children and young adults with transvenous lead systems
Abstract
Background: Venous occlusion is a recognized complication of transvenous pacing, and lead cross-sectional area indexed to body surface area (BSA) has been used to predict venous obstruction in children.
Objective: The aim of this study was to identify the risk factors and incidence of angiographic venous obstruction after transvenous lead implantation in both children and young adults.
Methods: Contrast venography was obtained in 85 of 90 consecutive patients undergoing repeat pacemaker or ICD procedures from 2002 to 2004 at a single cardiac center. Venograms were graded as complete venous obstruction, significant partial obstruction (>70% with collaterals), or patent.
Results: The cohort had a median age of 15.0 years at implant and was divided into two age groups: 3-12 years (n = 35) and 13 years and over (n = 50). After a median interval of 6.5 years, complete obstruction was seen in 11 of 85 patients (13%) and partial obstruction in another 10 patients (12%). No significant differences were seen in the incidence of obstruction between the two age groups although younger patients had a larger lead indexed to BSA ratio (6.82 vs 5.05, P = 0.005). There were no significant differences between obstructed and nonobstructed patients in relation to age, size, growth, or lead factors.
Conclusion: Transvenous lead systems implanted in young children have a similar incidence of venous occlusion compared to older patients. Furthermore, patient age, body size, and lead characteristics at implant do not clearly predict venous occlusion.
Comment in
-
Complications of cardiac pacing in children: does size matter?J Cardiovasc Electrophysiol. 2006 Jul;17(7):760-2. doi: 10.1111/j.1540-8167.2006.00510.x. J Cardiovasc Electrophysiol. 2006. PMID: 16836674 No abstract available.
Similar articles
-
Predictors of venous obstruction following pacemaker or implantable cardioverter-defibrillator implantation: a contrast venographic study on 100 patients admitted for generator change, lead revision, or device upgrade.Europace. 2007 May;9(5):328-32. doi: 10.1093/europace/eum019. Epub 2007 Mar 16. Europace. 2007. PMID: 17369270
-
Upper extremity deep venous thrombosis and stenosis after implantation of pacemakers and defibrillators; A prospective study.Rom J Intern Med. 2017 Sep 26;55(3):139-144. doi: 10.1515/rjim-2017-0018. Rom J Intern Med. 2017. PMID: 28432849
-
Venous Stenosis After Transvenous Lead Placement: A Study of Outcomes and Risk Factors in 212 Consecutive Patients.J Am Heart Assoc. 2015 Jul 31;4(8):e001878. doi: 10.1161/JAHA.115.001878. J Am Heart Assoc. 2015. PMID: 26231843 Free PMC article.
-
Lead-Related Venous Obstruction in Patients With Implanted Cardiac Devices: JACC Review Topic of the Week.J Am Coll Cardiol. 2022 Jan 25;79(3):299-308. doi: 10.1016/j.jacc.2021.11.017. J Am Coll Cardiol. 2022. PMID: 35057916 Review.
-
Venous thrombosis and stenosis after implantation of pacemakers and defibrillators.J Interv Card Electrophysiol. 2005 Jun;13(1):9-19. doi: 10.1007/s10840-005-1140-1. J Interv Card Electrophysiol. 2005. PMID: 15976973 Review.
Cited by
-
Impact of transvenous ventricular pacing leads on tricuspid regurgitation in pediatric and congenital heart disease patients.J Interv Card Electrophysiol. 2008 Jan;21(1):65-8. doi: 10.1007/s10840-007-9183-0. Epub 2007 Nov 27. J Interv Card Electrophysiol. 2008. PMID: 18040765 Free PMC article.
-
Efficacy and safety of non-transvenous cardioverter defibrillators in infants and young children.J Interv Card Electrophysiol. 2019 Mar;54(2):151-159. doi: 10.1007/s10840-018-0451-y. Epub 2018 Sep 25. J Interv Card Electrophysiol. 2019. PMID: 30255451
-
Case series of late lead dislodgement of Medtronic SelectSecure 3830 pacing leads in growing paediatric patients.Eur Heart J Case Rep. 2021 Jan 12;5(2):ytaa545. doi: 10.1093/ehjcr/ytaa545. eCollection 2021 Feb. Eur Heart J Case Rep. 2021. PMID: 33598620 Free PMC article.
-
A computer modeling tool for comparing novel ICD electrode orientations in children and adults.Heart Rhythm. 2008 Apr;5(4):565-72. doi: 10.1016/j.hrthm.2008.01.018. Epub 2008 Jan 17. Heart Rhythm. 2008. PMID: 18362024 Free PMC article.
-
Transvenous endocardial pacing with SelectSecure™ 3830 lead in pediatric patients: case series of two infants and a literature review.BMC Cardiovasc Disord. 2024 Mar 5;24(1):145. doi: 10.1186/s12872-024-03820-3. BMC Cardiovasc Disord. 2024. PMID: 38443792 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical