Use of vancomycin-containing lock or flush solutions for prevention of bloodstream infection associated with central venous access devices: a meta-analysis of prospective, randomized trials
- PMID: 16838237
- DOI: 10.1086/505976
Use of vancomycin-containing lock or flush solutions for prevention of bloodstream infection associated with central venous access devices: a meta-analysis of prospective, randomized trials
Abstract
Background: Prolonged exposure to central venous access devices carries significant risk of device-associated bloodstream infection (BSI), which is associated with morbidity, added health care costs, and attributable mortality. We aimed to determine the efficacy of vancomycin-heparin lock or flush solution in preventing BSI in patients being treated with long-term central venous intravascular devices (IVDs).
Methods: We collected data from January 1966 to January 2006 from multiple computerized databases and compiled reference lists of identified articles. We identified prospective, randomized controlled trials comparing a vancomycin-heparin lock or flush solution with heparin alone for prevention of BSI associated with long-term central venous IVDs. Using a standardized form, we abstracted data regarding study quality, patient characteristics, and incidence of BSI.
Results: Seven randomized, controlled trials involving a total of 463 patients being treated with IVDs met the inclusion criteria; 5 studies were conducted among patients with cancer, 1 among a critically ill neonatal population, and 1 among patients with cancer or who required parenteral nutrition. We could not detect publication bias. The summary risk ratio with a vancomycin heparin-lock solution for IVD-associated BSI was 0.49 (95% confidence interval [CI], 0.26-0.95; P = .03). Results of the test for heterogeneity were statistically significant; however, when a single study was removed from the analysis, heterogeneity was no longer present. Use of vancomycin as a true lock solution--instilling it for a defined period, rather than simply flushing it directly through the device--conferred a much greater benefit, with a risk ratio of 0.34 (95% CI, 0.12-0.98; P = .04). The 2 studies that performed prospective surveillance cultures to identify colonization or infection by vancomycin-resistant organisms did not find an increased risk.
Conclusions: Use of a vancomycin lock solution in high-risk patient populations being treated with long-term central IVDs reduces the risk of BSI. The use of an anti-infective lock solution warrants consideration for patients who require central access but who are at high risk of BSI, such as patients with malignancy or low-birthweight neonates.
Similar articles
-
A vancomycin-heparin lock solution for prevention of nosocomial bloodstream infection in critically ill neonates with peripherally inserted central venous catheters: a prospective, randomized trial.Pediatrics. 2005 Aug;116(2):e198-205. doi: 10.1542/peds.2004-2674. Epub 2005 Jul 1. Pediatrics. 2005. PMID: 15995005 Clinical Trial.
-
Urokinase lock or flush solution for prevention of bloodstream infections associated with central venous catheters for chemotherapy: a meta-analysis of prospective randomized trials.J Vasc Access. 2008 Jan-Mar;9(1):51-7. J Vasc Access. 2008. PMID: 18379981
-
Fusidic acid and heparin lock solution for the prevention of catheter-related bloodstream infections in critically ill neonates: a retrospective study and a prospective, randomized trial.Pediatr Crit Care Med. 2007 Nov;8(6):556-62. doi: 10.1097/01.PCC.0000288711.46009.58. Pediatr Crit Care Med. 2007. PMID: 17914310 Clinical Trial.
-
Nosocomial catheter-related bloodstream infections in a pediatric intensive care unit: risk and rates associated with various intravascular technologies.Pediatr Crit Care Med. 2003 Oct;4(4):432-6. doi: 10.1097/01.PCC.0000090286.24613.40. Pediatr Crit Care Med. 2003. PMID: 14525637
-
Rates of infection for single-lumen versus multilumen central venous catheters: a meta-analysis.Crit Care Med. 2003 Sep;31(9):2385-90. doi: 10.1097/01.CCM.0000084843.31852.01. Crit Care Med. 2003. PMID: 14501971 Review.
Cited by
-
Antibiotic lock for the prevention of catheter-related infection in neonates.Cochrane Database Syst Rev. 2015 Jun 4;2015(6):CD010336. doi: 10.1002/14651858.CD010336.pub2. Cochrane Database Syst Rev. 2015. PMID: 26040840 Free PMC article.
-
Rhodococcus bacteremia in cancer patients is mostly catheter related and associated with biofilm formation.PLoS One. 2012;7(3):e32945. doi: 10.1371/journal.pone.0032945. Epub 2012 Mar 13. PLoS One. 2012. PMID: 22427914 Free PMC article.
-
Moving CLABSI prevention beyond the intensive care unit: risk factors in pediatric oncology patients.Infect Control Hosp Epidemiol. 2011 Nov;32(11):1079-85. doi: 10.1086/662376. Epub 2011 Sep 20. Infect Control Hosp Epidemiol. 2011. PMID: 22011534 Free PMC article.
-
Bacterial bloodstream infections in the allogeneic hematopoietic cell transplant patient: new considerations for a persistent nemesis.Bone Marrow Transplant. 2017 Aug;52(8):1091-1106. doi: 10.1038/bmt.2017.14. Epub 2017 Mar 27. Bone Marrow Transplant. 2017. PMID: 28346417 Review.
-
Ultraviolet-C irradiation for prevention of central venous catheter-related infections: an in vitro study.Photochem Photobiol. 2011 Jan-Feb;87(1):250-5. doi: 10.1111/j.1751-1097.2010.00819.x. Epub 2010 Nov 12. Photochem Photobiol. 2011. PMID: 21073470 Free PMC article.