Magnetic resonance-guided interstitial therapy for vaginal recurrence of endometrial cancer

Affiliations

Magnetic resonance-guided interstitial therapy for vaginal recurrence of endometrial cancer

Akila N Viswanathan et al. Int J Radiat Oncol Biol Phys. .

Abstract

Purpose: To evaluate the feasibility and to describe the acute toxicity of a real-time intraoperative magnetic resonance (MR)-image guided interstitial approach to treating vaginal recurrence of endometrial cancer.

Methods and materials: From February 2004 to April 2005, 10 patients with recurrent endometrial cancer underwent MR-guided interstitial brachytherapy. Parameters evaluated included needle placement, dose-volume histograms (DVH), and complications.

Results: Magnetic resonance-image guidance resulted in accurate needle placement. Tumor DVH values included median volume, 47 cc; V100, 89%; V150, 61%; V200, 38%; D90, 71 Gy; and D100, 60 Gy. DVH of organs at risk resulted in a median D2cc of external beam and brachytherapy dose (% of brachytherapy prescription): bladder, 75Gy(3) (88%); rectum, 70Gy(3) (87%); and sigmoid, 56Gy(3) (41%). All patients experienced either a Grade 1 or 2 acute toxicity related to the radiation; only 1 patient had Grade 3 toxicity. No toxicities were attributable to the use of MR guidance.

Conclusions: Real-time MR guidance during the insertion of interstitial needles reduces the likelihood of an inadvertent insertion of the needles into the bladder and the rectum. Three-dimensional dosimetry allows estimation of the dose to organs at risk. Toxicities are limited.