Variability of airborne microflora in a hospital ward within a period of one year
- PMID: 16841880
Variability of airborne microflora in a hospital ward within a period of one year
Abstract
The aim of the study was to determine the seasonal variability of the airborne microflora in a hospital ward of the pneumonological department, with regard to potential impact on respiratory status of asthmatic patients hospitalized in the ward. Microbiological air sampling was carried out for a period of 1 year from June-May, during work-days, 16-21 days per month. Each day, the air samples were collected twice: in the morning at 09:00 and in the afternoon at 13:00. Air samples were taken with a custom-designed particle-sizing slit sampler enabling estimations of both total and respirable fractions of the microbial aerosol. Air samples for determination of bacteria were taken on blood agar and air samples for determination of fungi were taken on Sabouraud agar. Mean monthly concentrations of total microorganisms (bacteria + fungi) in the air of the examined hospital ward were between 296.1-529.9 cfu/m3. Mean monthly concentrations of airborne bacteria ranged from 257.1-436.3 cfu/m3, with peak values in November and May and the lowest values from December to February. Mean monthly concentrations of airborne fungi showed much greater variation than bacteria and ranged from 9.9-96.1 cfu/m3 with the very distinct peak in November and the lowest value in May. The variations in monthly concentrations of total microorganisms, bacteria and fungi in the air of hospital ward were statistically significant (p < 0.001). The concentrations of total airborne microorganisms, bacteria and fungi recorded in the hospital in the morning were significantly greater compared to those recorded in the afternoon (p < 0.01). The mean monthly values of respirable fraction for total microorganisms were within a range of 17.3-44.4%, for bacteria within a range of 17.2-44.8%, and for fungi within a range of 2.2-39.1%. The most common microorganisms in the air of the examined ward were Gram-positive cocci which accounted for 31.4-46.4% of the total count. Gram-negative bacteria and corynebacteria were less numerous, forming respectively 11.8-27.5% and 9.6-20.0% of the total count. Endospore-forming bacilli and actinomycetes occurred in small proportions, respectively 0.3-3.2% and 0-2.0% of the total count. Fungi formed 7.6-42.5% of the total count. The prevailing species was Aspergillus fumigatus which constituted on average 77.0% of total fungal strains isolated from the air of the hospital ward. A significant decrease of spirographic indices (VC, FEV1) in asthmatic patients hospitalized in the ward, at increase of the concentration of airborne bacteria and/or fungi, was found in 9 out of 24 examined patients (37.5%) and in 19 out of 192 analysed single relationships (9.9%). In conclusion, although bacteria and fungi occurred in the air of the examined hospital ward in relatively low numbers (of the order 10(2) cfu/m3 and 10(1) cfu/m3 respectively), they should be considered as a possible cause of asthma exacerbations in some patients because of the presence of Aspergillus fumigatus and other potentially pathogenic species.
Similar articles
-
Exposure to airborne microorganisms and endotoxin in herb processing plants.Ann Agric Environ Med. 2001;8(2):201-11. Ann Agric Environ Med. 2001. PMID: 11748878
-
Exposure to airborne microorganisms in fiberboard and chipboard factories.Ann Agric Environ Med. 2001;8(2):191-9. Ann Agric Environ Med. 2001. PMID: 11748877
-
Exposure to airborne microorganisms in Polish sawmills.Ann Agric Environ Med. 2001;8(1):71-80. Ann Agric Environ Med. 2001. PMID: 11426928
-
Bacterial and fungal aerosols in indoor environment in Central and Eastern European countries.Ann Agric Environ Med. 2002;9(1):17-23. Ann Agric Environ Med. 2002. PMID: 12088392 Review.
-
Relevance of airborne fungi and their secondary metabolites for environmental, occupational and indoor hygiene.Arch Microbiol. 2003 Jan-Feb;179(2):75-82. doi: 10.1007/s00203-002-0495-2. Epub 2002 Dec 6. Arch Microbiol. 2003. PMID: 12560984 Review.
Cited by
-
A study of air microbe levels in different areas of a hospital.Curr Microbiol. 2009 Jul;59(1):53-8. doi: 10.1007/s00284-009-9398-7. Epub 2009 Mar 28. Curr Microbiol. 2009. PMID: 19330376
-
Microbiological assessment of indoor air of a teaching hospital in Nigeria.Asian Pac J Trop Biomed. 2012 Jun;2(6):465-8. doi: 10.1016/S2221-1691(12)60077-X. Asian Pac J Trop Biomed. 2012. PMID: 23569951 Free PMC article.
-
A systematic review and meta-analysis of indoor bioaerosols in hospitals: The influence of heating, ventilation, and air conditioning.PLoS One. 2021 Dec 23;16(12):e0259996. doi: 10.1371/journal.pone.0259996. eCollection 2021. PLoS One. 2021. PMID: 34941879 Free PMC article.
-
Assessment of Bacterial Pathogens and their Antibiotic Resistance in the Air of Different Wards of Selected Teaching Hospitals in Tehran.Indian J Occup Environ Med. 2021 Apr-Jun;25(2):78-83. doi: 10.4103/ijoem.IJOEM_234_19. Epub 2021 Jul 9. Indian J Occup Environ Med. 2021. PMID: 34421242 Free PMC article.
-
Air Contamination in Different Departments of a Tertiary Hospital. Assessment of Microbial Load and of Antimicrobial Susceptibility.Biomedicines. 2020 Jun 17;8(6):163. doi: 10.3390/biomedicines8060163. Biomedicines. 2020. PMID: 32560299 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical