Integrated preconcentration SDS-PAGE of proteins in microchips using photopatterned cross-linked polyacrylamide gels
Abstract
The potential of integration of functions in microfluidic chips is demonstrated by implementing on-chip preconcentration of proteins prior to on-chip protein sizing by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Two polymeric elements-a thin (approximately 50 microm) size exclusion membrane for preconcentration and a longer (approximately cm) porous monolith for protein sizing-were fabricated in situ using photopolymerization. Contiguous placement of the two polymeric elements in the channels of a microchip enabled simple and zero dead volume integration of the preconcentration with SDS-PAGE. The size exclusion membrane was polymerized in the injection channel using a shaped laser beam, and the sizing monolith was cast by photolithography using a mask and UV lamp. Proteins injected electrophoretically were trapped on the upstream side of the size exclusion membrane (MW cutoff approximately 10 kDa) and eluted off the membrane by reversing the electric field. Subsequently, the concentrated proteins were separated in a cross-linked polyacrylamide monolith that was patterned contiguous to the size exclusion membrane. The extent of protein preconcentration is easily tuned by varying the voltage during injection or by controlling the sample volume loaded. Electric fields applied across the nanoporous membrane resulted in a concentration polarization effect evidenced by decreasing current over time and irreproducible migration of proteins during sizing. To minimize the concentration polarization effect, sieving gels were polymerized only on the separation side of the membrane, and an alternate electrical current path was employed, bypassing the membrane, for most of the elution and separation steps. Electrophoretically sweeping a fixed sample volume against the membrane yields preconcentration factors that are independent of protein mobility. The volume sweeping method also avoids biased protein loading from concentration polarization and sample matrix variations. Mobilities of the concentrated proteins were log-linear with respect to molecular weight, demonstrating the suitability of this approach for protein sizing. Proteins were concentrated rapidly (<5 min) over 1000-fold followed by high-resolution separation in the sieving monolith. Proteins with concentrations as low as 50 fM were detectable with 30 min of preconcentration time. The integrated preconcentration-sizing approach facilitates analysis of low-abundant proteins that cannot be otherwise detected. Moreover, the integrated preconcentration-analysis approach employing in situ formation of photopatterned polymeric elements provides a generic, inexpensive, and versatile method to integrate functions at chip level and can be extended to lowering of detection limits for other applications such as DNA analysis and clinical diagnostics.
Similar articles
-
Photopolymerized cross-linked polyacrylamide gels for on-chip protein sizing.Anal Chem. 2004 Aug 15;76(16):4727-33. doi: 10.1021/ac049686u. Anal Chem. 2004. PMID: 15307783
-
Microchip dialysis of proteins using in situ photopatterned nanoporous polymer membranes.Anal Chem. 2004 Apr 15;76(8):2367-73. doi: 10.1021/ac035290r. Anal Chem. 2004. PMID: 15080749
-
Preconcentration of proteins on microfluidic devices using porous silica membranes.Anal Chem. 2005 Jan 1;77(1):57-63. doi: 10.1021/ac049136w. Anal Chem. 2005. PMID: 15623278
-
Comparison of selected analytical techniques for protein sizing, quantitation and molecular weight determination.J Biochem Biophys Methods. 2004 Sep 30;60(3):281-93. doi: 10.1016/j.jbbm.2004.01.007. J Biochem Biophys Methods. 2004. PMID: 15345296 Review.
-
Recent progress of online sample preconcentration techniques in microchip electrophoresis.J Sep Sci. 2008 Aug;31(14):2650-66. doi: 10.1002/jssc.200800272. J Sep Sci. 2008. PMID: 18693308 Review.
Cited by
-
10,000-fold concentration increase in proteins in a cascade microchip using anionic ITP by a 3-D numerical simulation with experimental results.Electrophoresis. 2011 Feb;32(5):550-62. doi: 10.1002/elps.201000510. Epub 2011 Feb 10. Electrophoresis. 2011. PMID: 21308695 Free PMC article.
-
Microfluidic immunoassays as rapid saliva-based clinical diagnostics.Proc Natl Acad Sci U S A. 2007 Mar 27;104(13):5268-73. doi: 10.1073/pnas.0607254104. Epub 2007 Mar 20. Proc Natl Acad Sci U S A. 2007. PMID: 17374724 Free PMC article.
-
Microscale Interfacial Polymerization on a Chip.Angew Chem Int Ed Engl. 2021 Nov 2;60(45):24064-24069. doi: 10.1002/anie.202110974. Epub 2021 Oct 5. Angew Chem Int Ed Engl. 2021. PMID: 34460136 Free PMC article.
-
Automated microfluidic protein immunoblotting.Nat Protoc. 2010 Nov;5(11):1844-56. doi: 10.1038/nprot.2010.142. Epub 2010 Oct 28. Nat Protoc. 2010. PMID: 21030959
-
Ion-permeable membrane for on-chip preconcentration and separation of cancer marker proteins.Electrophoresis. 2011 May;32(10):1133-40. doi: 10.1002/elps.201000698. Electrophoresis. 2011. PMID: 21544838 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous