Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Dec;92(12):1821-6.
doi: 10.1136/hrt.2006.089060. Epub 2006 Jul 19.

Increased C reactive protein and cardiac enzyme levels after coronary stent implantation. Is there protection by remote ischaemic preconditioning?

Affiliations

Increased C reactive protein and cardiac enzyme levels after coronary stent implantation. Is there protection by remote ischaemic preconditioning?

E K Iliodromitis et al. Heart. 2006 Dec.

Abstract

Aim: To investigate whether remote ischaemic preconditioning (RIPC) can attenuate the inflammatory response and enzyme leakage that can occur after uncomplicated routine percutaneous coronary intervention (PCI).

Methods: 41 consecutive normotensive patients with stable angina and single-vessel disease were assigned to be exposed to RIPC (n = 20) or not (control group; n = 21) before elective PCI with stent implantation. RIPC was induced by three cycles of 5-min ischaemia-reperfusion of both upper limbs (inflation/deflation of blood pressure cuff). C reactive protein (CRP), creatine phosphokinase (CK), CK cardiac isoenzyme (CK-MB) and troponin I (TNI) were serially measured for 48 h.

Results: No difference in baseline values was observed between the groups. The CRP rose significantly (p<0.001) and at 48 h was similarly increased (>fourfold) in both groups (15.7 (2.6) v 14.0 (3.3) mg/l, RIPC v control; p = NS). However, sub-group analysis on the basis of statin use showed that the highest rise was in the group of patients with RIPC not taking statins and was significantly greater than in patients with RIPC taking statins (23.8 (3.71) v 11.4 (3.0) mg/l, respectively, p<0.01). Both CK-MB and TNI leakage were raised (slightly but significantly) after PCI in controls at 24 h compared with baseline values. However, this small rise was significantly worse after RIPC (CK-MB, 1.33 (0.27) v 3.57 (0.97) ng/ml, p<0.01; TNI, 0.255 (0.059) v 0.804 (0.232) ng/ml, p<0.05, respectively at 24 h). The increase was more marked in the RIPC subgroup not taking statins.

Conclusions: RIPC does not reduce, but exacerbates, the enzyme and TNI release from the heart after single-vessel angioplasty with stent. Furthermore, the increased circulating CRP remains raised. It seems that there is an enhanced inflammatory response after RIPC in the absence of statin treatment.

PubMed Disclaimer

Conflict of interest statement

Competing interests: None declared.

References

    1. Almagor M, Keren A, Banai S. Increased C‐reactive protein level after coronary stent implantation in patients with stable coronary artery disease. Am Heart J 2003145248–253. - PubMed
    1. Moliterno D J, Penn M S. Angioplasty, inflammation, and antiplatelet agents. Am Heart J 2003145563–566. - PubMed
    1. Gomes W J, Giannotti‐Filho O, Paez R P.et al Coronary artery and myocardial inflammatory reaction induced by intracoronary stent. Ann Thorac Surg 2003761528–1532. - PubMed
    1. Kini A S, Lee P, Marmur J D.et al Correlation of postpercutaneous coronary intervention creatine kinase‐MB and troponin I elevation in predicting mid‐term mortality. Am J Cardiol 20049318–23. - PubMed
    1. Saadeddin S M, Habbab M A, Sobki S H.et al Biochemical detection of minor myocardial injury after elective, uncomplicated, successful percutaneous coronary intervention in patients with stable angina: clinical outcome. Ann Clin Biochem 200239(Pt 4)392–397. - PubMed