Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Sep;30(9):1658-63; discussion 1664.
doi: 10.1007/s00268-005-0660-2.

Surgeon-performed ultrasound for preoperative localization of abnormal parathyroid glands in patients with primary hyperparathyroidism

Affiliations

Surgeon-performed ultrasound for preoperative localization of abnormal parathyroid glands in patients with primary hyperparathyroidism

John C Kairys et al. World J Surg. 2006 Sep.

Abstract

Background: The introduction of portable ultrasound equipment enables surgeons to perform ultrasound examinations in a clinic setting. This study was undertaken to evaluate surgeon-performed ultrasound (SP-US) in patients with primary hyperparathyroidism (PHPT).

Methods: Between July 2003 and March 2004, 65 patients with PHPT were evaluated with SP-US and 48 of these patients underwent parathyroid surgery. Among this group of 48 evaluable patients, 47 had preoperative imaging with technetium-99m sestamibi scanning (MIBI), and 12 had an additional ultrasound examination at an external radiology department (RP-US).

Results: All patients were cured of PHPT and the operative findings were used to determine the true status of the parathyroid glands of each patient. Twenty-four (50%) patients had concomitant thyroid nodules which were identified by SP-US, and 4 (8.3%) patients had simultaneous thyroid operations, 2 of which were for thyroid cancer. Considering data for all patients, SP-US had significantly higher sensitivity than MIBI or RP-US (60% vs. 46%, P = 0.013, and 60% vs. 11%, P = 0.004 respectively). Among the patients with a single adenoma, SP-US, MIBI, and RP-US had sensitivities of 83%, 63%, and 13% respectively. The specificities of all three imaging techniques were uniformly high and were not significantly different from each other.

Conclusions: Surgeon-performed ultrasound is an accurate modality for localizing abnormal parathyroid glands in patients with PHPT, with results that compare favorably with other parathyroid imaging modalities.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Nucl Med Commun. 2003 Jul;24(7):755-62 - PubMed
    1. World J Surg. 2002 Aug;26(8):926-30 - PubMed
    1. Endocr Relat Cancer. 2001 Mar;8(1):63-9 - PubMed
    1. Ann Surg Oncol. 2002 Dec;9(10 ):988-93 - PubMed
    1. Surg Clin North Am. 1995 Jun;75(3):483-98 - PubMed

Substances

LinkOut - more resources