Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Dec;33(12):1491-9.
doi: 10.1007/s00259-006-0155-x. Epub 2006 Jul 21.

Quantification of [123I]FP-CIT SPECT brain images: an accurate technique for measurement of the specific binding ratio

Affiliations

Quantification of [123I]FP-CIT SPECT brain images: an accurate technique for measurement of the specific binding ratio

Livia Tossici-Bolt et al. Eur J Nucl Med Mol Imaging. 2006 Dec.

Abstract

Purpose: A technique is described for accurate quantification of the specific binding ratio (SBR) in [(123)I]FP-CIT SPECT brain images.

Methods: Using a region of interest (ROI) approach, the SBR is derived from a measure of total striatal counts that takes into account the partial volume effect. Operator intervention is limited to the placement of the striatal ROIs, a task facilitated by the use of geometrical template regions. The definition of the image for the analysis is automated and includes transaxial slices within a "slab" approximately 44 mm thick centred on the highest striatal signal. The reference region is automatically defined from the non-specific uptake in the whole brain enclosed in the slab, with exclusion of the striatal region. A retrospective study consisting of 25 normal and 30 abnormal scans-classified by the clinical diagnosis reached with the scan support-was carried out to assess intra- and inter-operator variability of the technique and its clinical usefulness. Three operators repeated the quantification twice and the variability was measured by the coefficient of variation (COV).

Results: The COVs for intra- and inter-operator variability were 3% and 4% respectively. A cutoff approximately 4.5 was identified that separated normal and abnormal groups with a sensitivity, specificity and diagnostic concordance of 97%, 92% and 95% respectively.

Conclusion: The proposed technique provides a reproducible and sensitive index. It is hoped that its independence from the partial volume effect will improve consistency in quantitative measurements between centres with different imaging devices and analysis software.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Eur J Nucl Med. 2000 Nov;27(11):1714-8 - PubMed
    1. J Neurol Neurosurg Psychiatry. 2002 Aug;73(2):134-40 - PubMed
    1. Eur J Nucl Med. 2001 Oct;28(10):1523-8 - PubMed
    1. J Nucl Med. 1998 Nov;39(11):1879-84 - PubMed
    1. Nucl Med Commun. 1999 Feb;20(2):159-65 - PubMed

Substances

LinkOut - more resources