The vagaries of ear temperature assessment
- PMID: 16864236
- DOI: 10.1080/03091900600711415
The vagaries of ear temperature assessment
Abstract
There have been a growing number of reports suggesting that ear temperature measurement is unreliable and by implication so is the device. Examination of the measurement site, the tympanic membrane (eardrum) and the walls of the external auditory meatus (ear canal) reveals that at least some of the unreliability might derive from poor aiming of the infrared thermometer: the ear canal walls have a lower temperature than the eardrum. Additionally, anatomical properties of the ear canal may increase the difficulty of aiming the thermometer at the eardrum. Furthermore, the rich vascularization, innervation and variations in skin properties (thickness, oil secretion and hair) along the length of the ear canal affect the black body-like nature of the structure. It is concluded that such factors are more likely underlying reasons for the difficulties in reliably reproducing temperatures from this site. We conclude that concerns should extend beyond the reliability of the device and there should be greater study of the measurement site. The argument extends to all sites chosen for clinical assessment of the patient, as previous studies of the alternative temperature measurement sites are also unfortunately few and tend to be lacking in scientific rigour.
Similar articles
-
Infrared tympanic temperature and ear canal morphology.J Med Eng Technol. 2006 Jul-Aug;30(4):224-34. doi: 10.1080/03091900600711613. J Med Eng Technol. 2006. PMID: 16864234 Clinical Trial.
-
[Can ear temperature measurement be used in a hospital?].Tidsskr Nor Laegeforen. 2005 Oct 20;125(20):2763-5. Tidsskr Nor Laegeforen. 2005. PMID: 16244675 Norwegian.
-
The effect of factors such as handedness, sex and age on body temperature measured by an infrared 'tympanic' thermometer.J Med Eng Technol. 2006 Jul-Aug;30(4):235-41. doi: 10.1080/03091900600711324. J Med Eng Technol. 2006. PMID: 16864235 Clinical Trial.
-
Accuracy of noninvasive core temperature measurement in acutely ill adults: the state of the science.Biol Res Nurs. 2006 Jul;8(1):24-34. doi: 10.1177/1099800406289151. Biol Res Nurs. 2006. PMID: 16766626 Review.
-
The accuracy of infrared auditory canal thermometry in infants and children.Clin Pediatr (Phila). 1993 Jun;32(6):347-54. doi: 10.1177/000992289303200605. Clin Pediatr (Phila). 1993. PMID: 8344045 Review. No abstract available.
Cited by
-
Evaluation of performance and uncertainty of infrared tympanic thermometers.Sensors (Basel). 2010;10(4):3073-89. doi: 10.3390/s100403073. Epub 2010 Mar 31. Sensors (Basel). 2010. PMID: 22319287 Free PMC article.
-
Low Ambient Temperature Exposition Impairs the Accuracy of a Non-invasive Heat-Flux Thermometer.Front Physiol. 2022 Mar 4;13:830059. doi: 10.3389/fphys.2022.830059. eCollection 2022. Front Physiol. 2022. PMID: 35309078 Free PMC article.
-
SARS-CoV-2 (Covid-19) workplace temperature screening: Seasonal concerns for thermal detection in northern regions.Appl Ergon. 2022 Jan;98:103576. doi: 10.1016/j.apergo.2021.103576. Epub 2021 Sep 1. Appl Ergon. 2022. PMID: 34488191 Free PMC article.
-
Effect of whole-body mild-cold exposure on arterial stiffness and central haemodynamics: a randomised, cross-over trial in healthy men and women.Eur J Appl Physiol. 2013 May;113(5):1257-69. doi: 10.1007/s00421-012-2543-1. Epub 2012 Nov 18. Eur J Appl Physiol. 2013. PMID: 23160656 Clinical Trial.
-
Predictors of Conversion to Dementia in Patients With Mild Cognitive Impairment: The Role of Low Body Temperature.J Clin Med Res. 2023 Apr;15(4):216-224. doi: 10.14740/jocmr4883. Epub 2023 Apr 28. J Clin Med Res. 2023. PMID: 37187716 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources