Neointima inhibition: comparison of effectiveness of non-stent-based local drug delivery and a drug-eluting stent in porcine coronary arteries

Affiliations
Comparative Study

Neointima inhibition: comparison of effectiveness of non-stent-based local drug delivery and a drug-eluting stent in porcine coronary arteries

Ulrich Speck et al. Radiology. 2006 Aug.

Abstract

Purpose: To compare the inhibition of neointimal proliferation by using non-stent-based local drug delivery and a drug-eluting stent in porcine coronary arteries.

Materials and methods: Experiments were conducted with permission of the animal protection committee of the local government. Paclitaxel was either dissolved in a nonionic contrast medium or coated on balloons. Stents were crimped on the coated balloons. Effectiveness was tested in 22 pigs. Two coronary stents were placed in each pig, and slight overstretch was applied. The animals were treated as follows: group A (control group), uncoated balloons, bare stents, and "plain" contrast medium; group B, same treatment as group A, but with paclitaxel in the contrast medium; group C, paclitaxel-coated balloons, with premounted bare stents and plain contrast medium; and group D, sirolimus-eluting stents, noncoated balloons, and plain contrast medium. Stenosis was assessed 4 weeks later at angiography and histomorphometry. For exploratory purposes, continuous variables of quantitative coronary angiography and histomorphometry were compared by using analysis of variance.

Results: Results at follow-up angiography indicated a mean of 1.00 mm +/- 0.18 (standard deviation) lumen diameter loss in the control group and 0.14 mm +/- 0.18 loss in the group treated with the paclitaxel-coated balloon (group C; P < .001). Findings at histomorphometry confirmed the effectiveness of drug delivery, with the most impressive inhibition of neointimal proliferation from coated balloons-the neointimal area was 2.4 mm2 +/- 0.3 (P < .01 vs all other groups), compared with 5.2 mm2 +/- 0.3 in group A (control group), 4.3 mm2 +/- 0.3 in group B, and 3.8 mm2 +/- 0.3 in group D.

Conclusion: In spite of the short intima contact time, paclitaxel coated on the balloon inhibits neointimal formation in the porcine model of coronary stent placement.