Quantification of a cytochrome P450 3A4 substrate, buspirone, in human plasma by liquid chromatography-tandem mass spectrometry
- PMID: 16875888
- DOI: 10.1016/j.jchromb.2006.07.005
Quantification of a cytochrome P450 3A4 substrate, buspirone, in human plasma by liquid chromatography-tandem mass spectrometry
Abstract
A sensitive HPLC-tandem mass spectrometry method was developed for determination of buspirone levels in human plasma. After solid phase extraction and reversed phase HPLC separation, detection of buspirone and the internal standard (prazosin) was performed using eletrospray ionization and selected reaction monitoring in the positive ion mode. Linear calibration curves were established over a concentration range of 0.025-2.5 ng/ml when 0.5 ml aliquots of plasma were used. Satisfactory results of within-day precision (RSD of 1.9-7.7%) and accuracy (% difference of 0.5-6.6%) and between-day precision (RSD of 3.7-11.1%) and accuracy (% difference of 2.2-6.8%) were obtained. The assay has been successfully applied to the analysis of buspirone levels in more than 500 human plasma samples collected from a drug interaction study.
Similar articles
-
Rapid and highly sensitive liquid chromatography/electrospray ionization tandem mass spectrometry method for the quantitation of buspirone in human plasma: application to a pharmacokinetic study.Rapid Commun Mass Spectrom. 2006;20(8):1293-8. doi: 10.1002/rcm.2441. Rapid Commun Mass Spectrom. 2006. PMID: 16548054
-
Liquid chromatography/tandem mass spectrometry method for simultaneous evaluation of activities of five cytochrome P450s using a five-drug cocktail and application to cytochrome P450 phenotyping studies in rats.J Chromatogr B Analyt Technol Biomed Life Sci. 2008 Aug 1;871(1):78-89. doi: 10.1016/j.jchromb.2008.06.034. Epub 2008 Jun 27. J Chromatogr B Analyt Technol Biomed Life Sci. 2008. PMID: 18614408
-
High-sensitivity liquid chromatography-tandem mass spectrometry for the simultaneous determination of five drugs and their cytochrome P450-specific probe metabolites in human plasma.J Chromatogr B Analyt Technol Biomed Life Sci. 2012 May 1;895-896:56-64. doi: 10.1016/j.jchromb.2012.03.014. Epub 2012 Mar 19. J Chromatogr B Analyt Technol Biomed Life Sci. 2012. PMID: 22483397
-
Determination of geniposide in adjuvant arthritis rat plasma by ultra-high performance liquid chromatography tandem mass spectrometry method and its application to oral bioavailability and plasma protein binding ability studies.J Pharm Biomed Anal. 2015 Apr 10;108:122-8. doi: 10.1016/j.jpba.2015.01.044. Epub 2015 Feb 7. J Pharm Biomed Anal. 2015. PMID: 25771205
-
Quantitative determination of buagafuran in human plasma by liquid chromatography-tandem mass spectrometry.J Chromatogr B Analyt Technol Biomed Life Sci. 2011 Jun 15;879(20):1789-94. doi: 10.1016/j.jchromb.2011.04.029. Epub 2011 May 6. J Chromatogr B Analyt Technol Biomed Life Sci. 2011. PMID: 21606008 Clinical Trial.
Cited by
-
Resveratrol modulates drug- and carcinogen-metabolizing enzymes in a healthy volunteer study.Cancer Prev Res (Phila). 2010 Sep;3(9):1168-75. doi: 10.1158/1940-6207.CAPR-09-0155. Epub 2010 Aug 17. Cancer Prev Res (Phila). 2010. PMID: 20716633 Free PMC article. Clinical Trial.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources