Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Dec;90(12):1454-7.
doi: 10.1136/bjo.2006.099143. Epub 2006 Aug 2.

The role of scanning laser polarimetry using the GDx variable corneal compensator in the management of glaucoma suspects

Affiliations

The role of scanning laser polarimetry using the GDx variable corneal compensator in the management of glaucoma suspects

A Shaikh et al. Br J Ophthalmol. 2006 Dec.

Abstract

Aim: To determine the role of scanning laser polarimetry using the GDx variable corneal compensator (VCC) in the management of glaucoma suspects.

Methods: Over a 12-month period, 43 of 447 (9.6%) patients referred to a glaucoma screening clinic were classified as "glaucoma suspects" when it was not possible to categorise the optic disc appearance and visual fields as definitely glaucomatous or definitely normal. Of these patients, 39 underwent a full ophthalmic review, including assessment of the visual fields and analysis of the retinal nerve fibre layer with the GDx VCC.

Results: After the review, 17 of 39 (43.6%) patients were discharged because of normal GDx VCC results. The remaining 22 of 39 (56.4%) were considered to be at risk of developing progressive glaucoma, and further follow-up in the hospital eye service was recommended. 3 (7.7%) patients received treatment. Of the 22 patients, 12 were considered to have pre-perimetric normal tension glaucoma, 7 normal tension glaucoma and 1 primary open-angle glaucoma (POAG). In 19 of these patients, abnormal GDx VCC results were found, particularly inter-eye asymmetry in the nerve fibre layer thickness. However, in 2 of 39 (5.1%) patients the GDx VCC was normal, despite the presence of a neuroretinal rim defect in the optic disc with corresponding visual field loss, and in 1 patient with POAG.

Conclusions: Scanning laser polarimetry using the GDx VCC is an important tool in defining the management strategies of glaucoma suspects. In screening for glaucoma, however, GDx VCC results should not be used in isolation, but in conjunction with conventional methods of optic disc and visual field assessment.

PubMed Disclaimer

Conflict of interest statement

Competing interests: None declared.

Similar articles

Cited by

References

    1. Sommer A, Katz J, Quigley H A.et al Clinically detectable nerve fibre atrophy precedes the onset of glaucomatous field loss. Arch Ophthalmol 199110977–83. - PubMed
    1. Bowling B, Chen S D M, Salmon J F. Outcomes of referrals by community optometrists to a hospital glaucoma service. Br J Ophthalmol 2005891102–1104. - PMC - PubMed
    1. Reus N J, Lemij H G. Diagnostic accuracy of the GDx VCC for glaucoma. Ophthalmology 20041111860–1865. - PubMed
    1. Sommer A, Tielsch J M, Katz J.et al Relationship between intraocular pressure and primary open angle glaucoma among White and Black Americans. Arch Ophthalmol 19911091090–1095. - PubMed
    1. Collaborative Normal Tension Glaucoma Study Group Natural history of normal tension glaucoma. Ophthalmology 2001108247–253. - PubMed

Publication types