Multislice spiral computed tomography for the evaluation of stent patency after left main coronary artery stenting: a comparison with conventional coronary angiography and intravascular ultrasound
- PMID: 16894038
- DOI: 10.1161/CIRCULATIONAHA.105.608950
Multislice spiral computed tomography for the evaluation of stent patency after left main coronary artery stenting: a comparison with conventional coronary angiography and intravascular ultrasound
Abstract
Background: Surveillance conventional coronary angiography (CCA) is recommended 2 to 6 months after stent-supported left main coronary artery (LMCA) percutaneous coronary intervention due to the unpredictable occurrence of in-stent restenosis (ISR), with its attendant risks. Multislice computed tomography (MSCT) is a promising technique for noninvasive coronary evaluation. We evaluated the diagnostic performance of high-resolution MSCT to detect ISR after stenting of the LMCA.
Methods and results: Seventy-four patients were prospectively identified from a consecutive patient population scheduled for follow-up CCA after LMCA stenting and underwent MSCT before CCA. Until August 2004, a 16-slice scanner was used (n = 27), but we switched to the 64-slice scanner after that period (n = 43). Patients with initial heart rates > 65 bpm received beta-blockers, which resulted in a mean periscan heart rate of 57 +/- 7 bpm. Among patients with technically adequate scans (n = 70), MSCT correctly identified all patients with ISR (10 of 70) but misclassified 5 patients without ISR (false-positives). Overall, the accuracy of MSCT for detection of angiographic ISR was 93%. The sensitivity, specificity, and positive and negative predictive values were 100%, 91%, 67%, and 100%, respectively. When analysis was restricted to patients with stenting of the LMCA with or without extension into a single major side branch, accuracy was 98%. When both branches of the LMCA bifurcation were stented, accuracy was 83%. For the assessment of stent diameter and area, MSCT showed good correlation with intravascular ultrasound (r = 0.78 and 0.73, respectively). An intravascular ultrasound threshold value > or = 1 mm was identified to reliably detect in-stent neointima hyperplasia with MSCT.
Conclusions: Current MSCT technology, in combination with optimal heart rate control, allows reliable noninvasive evaluation of selected patients after LMCA stenting. MSCT is safe to exclude left main ISR and may therefore be an acceptable first-line alternative to CCA.
Comment in
-
Multislice computed tomography after left main drug-eluting stenting: are we putting the cart before the horse?Circulation. 2006 Aug 15;114(7):616-9. doi: 10.1161/CIRCULATIONAHA.106.645010. Circulation. 2006. PMID: 16908783 No abstract available.
Similar articles
-
Evaluation of coronary artery in-stent patency using 64-slice computed tomography.Coron Artery Dis. 2011 Dec;22(8):540-52. doi: 10.1097/MCA.0b013e32834c1a28. Coron Artery Dis. 2011. PMID: 21959714
-
Multislice CT for assessing in-stent dimensions after left main coronary artery stenting: a comparison with three dimensional intravascular ultrasound.Heart. 2013 Aug;99(15):1106-12. doi: 10.1136/heartjnl-2013-303679. Epub 2013 May 30. Heart. 2013. PMID: 23723447
-
Comparison of feasibility and diagnostic accuracy of 64-slice multidetector computed tomographic coronary angiography versus invasive coronary angiography versus intravascular ultrasound for evaluation of in-stent restenosis.Am J Cardiol. 2009 May 15;103(10):1349-58. doi: 10.1016/j.amjcard.2009.01.343. Epub 2009 Mar 25. Am J Cardiol. 2009. PMID: 19427427
-
Accuracy of multislice computed tomography coronary angiography: a pooled estimate.Cardiol Rev. 2008 Jul-Aug;16(4):189-96. doi: 10.1097/CRD.0b013e318164d02a. Cardiol Rev. 2008. PMID: 18562809 Review.
-
Noninvasive stent imaging with MSCT.EuroIntervention. 2009 May;5 Suppl D:D107-11. EuroIntervention. 2009. PMID: 19736058 Review.
Cited by
-
Cardiac Computed Tomography in Monitoring Revascularization.J Clin Med. 2023 Nov 15;12(22):7104. doi: 10.3390/jcm12227104. J Clin Med. 2023. PMID: 38002715 Free PMC article. Review.
-
Diagnostic accuracy of 64-slice computed tomography coronary angiography for the detection of in-stent restenosis: a meta-analysis.J Nucl Cardiol. 2010 Jun;17(3):470-8. doi: 10.1007/s12350-010-9218-2. Epub 2010 Apr 9. J Nucl Cardiol. 2010. PMID: 20379863 Free PMC article.
-
Multidetector computed tomography angiography for assessment of in-stent restenosis: meta-analysis of diagnostic performance.BMC Med Imaging. 2008 Jul 31;8:14. doi: 10.1186/1471-2342-8-14. BMC Med Imaging. 2008. PMID: 18671850 Free PMC article. Review.
-
Diagnostic performance of computed tomography angiography in the detection of coronary artery in-stent restenosis: evidence from an updated meta-analysis.Eur Radiol. 2018 Apr;28(4):1373-1382. doi: 10.1007/s00330-017-5097-0. Epub 2017 Nov 9. Eur Radiol. 2018. PMID: 29124384
-
Korean guidelines for the appropriate use of cardiac CT.Korean J Radiol. 2015 Mar-Apr;16(2):251-85. doi: 10.3348/kjr.2015.16.2.251. Epub 2015 Feb 27. Korean J Radiol. 2015. PMID: 25741189 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources