Integrating respiratory gating into a megavoltage cone-beam CT system
Abstract
We have previously described a low-dose megavoltage cone beam computed tomography (MV CBCT) system capable of producing projection image using one beam pulse. In this study, we report on its integration with respiratory gating for gated radiotherapy. The respiratory gating system tracks a reflective marker on the patient's abdomen midway between the xiphoid and umbilicus, and disables radiation delivery when the marker position is outside predefined thresholds. We investigate two strategies for acquiring gated scans. In the continuous rotation-gated acquisition, the linear accelerator (LINAC) is set to the fixed x-ray mode and the gantry makes a 5 min, 360 degree continuous rotation, during which the gating system turns the radiation beam on and off, resulting in projection images with an uneven distribution of projection angles (e.g., in 70 arcs each covering 2 degrees). In the gated rotation-continuous acquisition, the LINAC is set to the dynamic arc mode, which suspends the gantry rotation when the gating system inhibits the beam, leading to a slightly longer (6-7 min) scan time, but yielding projection images with more evenly distributed projection angles (e.g., approximately 0.8 degrees between two consecutive projection angles). We have tested both data acquisition schemes on stationary (a contrast detail and a thoracic) phantoms and protocol lung patients. For stationary phantoms, a separate motion phantom not visible in the images is used to trigger the RPM system. Frame rate is adjusted so that approximately 450 images (13 MU) are acquired for each scan and three-dimensional tomographic images reconstructed using a Feldkamp filtered backprojection algorithm. The gated rotation-continuous acquisition yield reconstructions free of breathing artifacts. The tumor in parenchymal lung and normal tissues are easily discernible and the boundary between the diaphragm and the lung sharply defined. Contrast-to-noise ratio (CNR) is not degraded relative to nongated scans of stationary phantoms. The continuous rotation-gated acquisition scan also yields tomographic images with discernible anatomic features; however, streak artifacts are observed and CNR is reduced by approximately a factor of 4. In conclusion, we have successfully developed a gated MV CBCT system to verify the patient positioning for gated radiotherapy.
Similar articles
-
Developments in megavoltage cone beam CT with an amorphous silicon EPID: reduction of exposure and synchronization with respiratory gating.Med Phys. 2005 Mar;32(3):819-29. doi: 10.1118/1.1861522. Med Phys. 2005. PMID: 15839355
-
Low-dose megavoltage cone-beam CT for radiation therapy.Int J Radiat Oncol Biol Phys. 2005 Feb 1;61(2):552-60. doi: 10.1016/j.ijrobp.2004.10.011. Int J Radiat Oncol Biol Phys. 2005. PMID: 15736320
-
Dual cardiac and respiratory gated thoracic imaging via adaptive gantry velocity and projection rate modulation on a linear accelerator: A Proof-of-Concept Simulation Study.Med Phys. 2019 Sep;46(9):4116-4126. doi: 10.1002/mp.13670. Epub 2019 Jul 5. Med Phys. 2019. PMID: 31220360
-
Cone-beam CT with megavoltage beams and an amorphous silicon electronic portal imaging device: potential for verification of radiotherapy of lung cancer.Med Phys. 2002 Dec;29(12):2913-24. doi: 10.1118/1.1517614. Med Phys. 2002. PMID: 12512728
-
Respiratory correlated cone beam CT.Med Phys. 2005 Apr;32(4):1176-86. doi: 10.1118/1.1869074. Med Phys. 2005. PMID: 15895601
Cited by
-
Streaking artifacts reduction in four-dimensional cone-beam computed tomography.Med Phys. 2008 Oct;35(10):4649-59. doi: 10.1118/1.2977736. Med Phys. 2008. PMID: 18975711 Free PMC article.
-
Autoadaptive phase-correlated (AAPC) reconstruction for 4D CBCT.Med Phys. 2009 Dec;36(12):5695-706. doi: 10.1118/1.3260919. Med Phys. 2009. PMID: 20095282 Free PMC article.
-
Dosimetric evaluation of respiratory gating on a 0.35-T magnetic resonance-guided radiotherapy linac.J Appl Clin Med Phys. 2022 Sep;23(9):e13666. doi: 10.1002/acm2.13666. Epub 2022 Aug 10. J Appl Clin Med Phys. 2022. PMID: 35950272 Free PMC article.
-
Monte Carlo investigations of megavoltage cone-beam CT using thick, segmented scintillating detectors for soft tissue visualization.Med Phys. 2008 Jan;35(1):145-58. doi: 10.1118/1.2818957. Med Phys. 2008. PMID: 18293571 Free PMC article.
-
Lag correction model and ghosting analysis for an indirect-conversion flat-panel imager.J Appl Clin Med Phys. 2007 Jul 23;8(3):137-146. doi: 10.1120/jacmp.v8i3.2483. J Appl Clin Med Phys. 2007. PMID: 17712306 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical
Research Materials