Rapid detection of Pneumocystis carinii in bronchoalveolar lavage samples by using Cellufluor staining
- PMID: 1690218
- PMCID: PMC269620
- DOI: 10.1128/jcm.28.2.393-394.1990
Rapid detection of Pneumocystis carinii in bronchoalveolar lavage samples by using Cellufluor staining
Abstract
Cellufluor (Calcofluor white) has been found to be a useful, rapid chemofluorescent stain for detection of Pneumocystis carinii cysts in bronchoalveolar lavage samples. When compared with toluidine blue O and Giemsa stains on 45 specimens (22 positive and 23 negative), the sensitivity and specificity of the Cellufluor stain were 95 and 100%, respectively.
Comment in
-
Cellufluor staining of bronchoalveolar lavage samples.J Clin Microbiol. 1992 Mar;30(3):754. doi: 10.1128/jcm.30.3.754-.1992. J Clin Microbiol. 1992. PMID: 1372623 Free PMC article. No abstract available.