. 2006 Aug 15;48(4):805-11.
doi: 10.1016/j.jacc.2006.03.055. Epub 2006 Jul 25.

Effects of cocaine intoxication on the threshold for stun gun induction of ventricular fibrillation

Affiliations
Free article

Effects of cocaine intoxication on the threshold for stun gun induction of ventricular fibrillation

Dhanunjaya Lakkireddy et al. J Am Coll Cardiol. .
Free article

Abstract

Objectives: This study sought to assess cocaine's effects on Taser-induced ventricular fibrillation (VF) threshold in a pig model.

Background: Stun guns are increasingly used by law enforcement officials to restrain violent subjects, who are frequently intoxicated with cocaine and other drugs of abuse. The interaction of cocaine and the stun gun on VF induction is unknown.

Methods: We tested five adult pigs using a custom device built to deliver multiples of standard neuromuscular incapacitating (NMI) discharge that matched the waveform of a commercially available electrical stun gun (Taser X-26, Taser International, Scottsdale, Arizona). The NMI discharges were applied in a step-up and step-down fashion at 5 body locations. End points included determination of maximum safe multiple, minimum VF-inducing multiple, and ventricular fibrillation threshold (VFT) before and after cocaine infusion.

Results: Standard NMI discharges (x1) did not cause VF at any of the 5 locations before or after cocaine infusion. The maximum safe multiple, minimum VF-inducing multiple, and VFT of NMI application increased with increasing electrode distance from the heart. There was a 1.5- to 2-fold increase in these values at each position after cocaine infusion, suggesting decreased cardiac vulnerability for VF. Cocaine increased the required strength of NMI discharge that caused 2:1 or 3:1 ventricular capture ratios at all of the positions. No significant changes in creatine kinase-MB and troponin-I were seen.

Conclusions: Cocaine increased the VFT of NMI discharges at all dart locations tested and reduced cardiac vulnerability to VF. The application of cocaine increased the safety margin by 50% to 100% above the baseline safety margin.

PubMed Disclaimer

Comment in

  • Taser research in pigs not helpful.
    Pippin JJ. Pippin JJ. J Am Coll Cardiol. 2007 Feb 13;49(6):731-2; author reply 732-3. doi: 10.1016/j.jacc.2006.11.019. Epub 2007 Jan 26. J Am Coll Cardiol. 2007. PMID: 17291944 No abstract available.

Publication types