Effect of aging on stereoscopic interocular correlation
- PMID: 16909084
- DOI: 10.1097/01.opx.0000230267.19805.75
Effect of aging on stereoscopic interocular correlation
Abstract
Purpose: This study was designed to evaluate the minimum interocular correlation (IOC) needed by the visual system to correctly perceive a static stereoscopic stimulus as a function of normal aging. It was also our goal to evaluate the feasibility of clinical charts testing this aspect of visual perception.
Methods: Stereoscopic IOC threshold was determined in 100 normal observers (average age +/- standard deviation, 45.7 +/- 20.4 years) drawn from a clinical population between the ages of 10 and 85. We used partially correlated red-green random dot stereograms (RDS) displaying flat, square surfaces at 360 arcsec of either crossed or uncrossed disparity.
Results: Older observers needed a higher binocular correlation to perceive the stereoscopic stimuli when compared with the younger groups. There is a slight increase in the threshold value of the individuals in the 45- to 64-year-old group and a further effect on the observers over 65 years of age. Data did not reveal any effects of gender, near point phoria, or fixation disparity on IOC thresholds.
Conclusions: Normal aging produces a statistically significant deficit in binocular correlation processing. This process is marginally correlated with stereo acuity measures even when stereoacuity floor effects are factored out. Although further experiments directly comparing stereoacuity and IOC are necessary and more refining is required to obtain optimum parameters, clinical stereoscopic IOC test charts appear feasible and may not assess the same processes as stereoacuity charts.
Similar articles
-
Effects of age and optical blur on real depth stereoacuity.Ophthalmic Physiol Opt. 2010 Sep;30(5):660-6. doi: 10.1111/j.1475-1313.2010.00750.x. Ophthalmic Physiol Opt. 2010. PMID: 20883352
-
Stereopsis and aging.Vision Res. 2008 Oct;48(23-24):2456-65. doi: 10.1016/j.visres.2008.08.008. Epub 2008 Sep 17. Vision Res. 2008. PMID: 18771680
-
The effects of interocular correlation and contrast on stereoscopic depth magnitude estimation.Optom Vis Sci. 2008 Mar;85(3):164-73. doi: 10.1097/OPX.0b013e3181643e65. Optom Vis Sci. 2008. PMID: 18317331
-
A new method for assessing motion-in-depth perception in strabismic patients.Br J Ophthalmol. 2008 Jan;92(1):47-50. doi: 10.1136/bjo.2007.117507. Epub 2007 Jun 27. Br J Ophthalmol. 2008. PMID: 17596334
-
Single image random dot stereogram: principles and clinical implications.J Am Optom Assoc. 1996 Apr;67(4):209-14. J Am Optom Assoc. 1996. PMID: 8888831 Review.
Cited by
-
Effects of Target Size and Test Distance on Stereoacuity.J Ophthalmol. 2016;2016:7950690. doi: 10.1155/2016/7950690. Epub 2016 Aug 21. J Ophthalmol. 2016. PMID: 27635256 Free PMC article.
-
Effects of horizontal acceleration on human visual acuity and stereopsis.Int J Environ Res Public Health. 2015 Jan 19;12(1):910-26. doi: 10.3390/ijerph120100910. Int J Environ Res Public Health. 2015. PMID: 25607601 Free PMC article.
-
Novel Glasses-Free Distance Stereotest Using Eye Tracking: Evaluation of Sensitivity, Validity, Reliability, and Monocular Cue Masking.J Multidiscip Healthc. 2025 Mar 28;18:1791-1801. doi: 10.2147/JMDH.S511165. eCollection 2025. J Multidiscip Healthc. 2025. PMID: 40171236 Free PMC article.
-
Stereoscopic Depth Perception and Visuospatial Dysfunction in Alzheimer's Disease.Healthcare (Basel). 2021 Feb 3;9(2):157. doi: 10.3390/healthcare9020157. Healthcare (Basel). 2021. PMID: 33546119 Free PMC article.
-
Individual and age-related variation in chromatic contrast adaptation.J Vis. 2012 Aug 17;12(8):11. doi: 10.1167/12.8.11. J Vis. 2012. PMID: 22904356 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical