Changes in aortic function after interposition of a tubular graft in the descending porcine thoracic aorta
- PMID: 16911316
- DOI: 10.1111/j.1525-1594.2006.00271.x
Changes in aortic function after interposition of a tubular graft in the descending porcine thoracic aorta
Abstract
The objective of the study was to investigate the alterations of aortic function after interposition of a tubular graft in the descending porcine thoracic aorta. Eight healthy Landrace pigs were subjected to thoracotomy under sterile conditions. A 5-cm-long segment of descending thoracic aorta was replaced with a Dacron graft. Pulse wave velocity (PWV) was measured using simultaneous recordings of electrocardiogram and Doppler pressure waveforms, which were received from right carotid and femoral arteries. Then, the recordings were fed to a computer for analytical estimation of PWV in several occasions: right after the interposition (D0), and after 15 (D15) and 30 (D30) days time. Euthanasia was performed after the D30-recordings and the aortic graft area was removed. "Before graft" (BG) as well as "after graft" (AG) aortic regions were examined under light microscopy in order to determine the aortic thickness (T) and number of lamellar units (LU). Eight sham-operated pigs were used as controls. The results showed that PWV decreased as soon as the graft interposition took place and was maintained, until the end of experiment (P < 0.05). Aortic wall thickness was increased both at pregraft and postgraft areas (P < 0.05), and LUs were also increased at the same regions. It is concluded that the interposition of a tubular graft in the descending thoracic aorta resulted in a decrease in PWV, which may improve left ventricular performance and enhance myocardial perfusion, due to a delay in the arrival of the reflecting diastolic wave.
Similar articles
-
Effect of an experimental stenosis in the porcine descending thoracic aorta.Artif Organs. 2004 Nov;28(11):987-92. doi: 10.1111/j.1525-1594.2004.00010.x. Artif Organs. 2004. PMID: 15504114
-
Pressure-flow loops and instantaneous input impedance in the thoracic aorta: another way to assess the effect of aortic bypass graft implantation on myocardial, brain, and subdiaphragmatic perfusion.J Thorac Cardiovasc Surg. 2003 Mar;125(3):699-710. doi: 10.1067/mtc.2003.104. J Thorac Cardiovasc Surg. 2003. PMID: 12658214
-
A minor experimental stenosis in porcine descending thoracic aorta affects the spectral content of pressure pulse wave.Artif Organs. 2004 Dec;28(12):1102-5. doi: 10.1111/j.1525-1594.2004.28122.x. Artif Organs. 2004. PMID: 15554939
-
[Change of paradigms in the surgical treatment of complex thoracic aortic disease].Herz. 2006 Aug;31(5):434-42. doi: 10.1007/s00059-006-2839-1. Herz. 2006. PMID: 16944063 German.
-
Endografting of the descending thoracic aorta increases ascending aortic input impedance and attenuates pressure transmission in dogs.Eur J Vasc Endovasc Surg. 2006 Aug;32(2):129-35. doi: 10.1016/j.ejvs.2006.01.020. Epub 2006 Mar 27. Eur J Vasc Endovasc Surg. 2006. PMID: 16564712
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous