Usefulness of live/real time three-dimensional transthoracic echocardiography in the assessment of atrioventricular septal defects
- PMID: 16911337
- DOI: 10.1111/j.1540-8175.2006.00268.x
Usefulness of live/real time three-dimensional transthoracic echocardiography in the assessment of atrioventricular septal defects
Abstract
We studied nine patients (five newborns and infants, two children, and two adults) with atrioventricular septal defects (four complete, one intermediate, and four partial) utilizing live/real time three-dimensional transthoracic echocardiography (3DTTE) and a 4-MHz matrix array transducer. In all patients, 3DTTE provided additional morphological and/or functional information as compared to standard two-dimensional transthoracic echocardiography (2DTTE). 3DTTE may be a useful supplement to 2DTTE in the assessment of atrioventricular septal defects.