Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Sep;64(3):345-52.
doi: 10.1111/j.1365-3083.2006.01826.x.

Microdialysis for monitoring inflammation: efficient recovery of cytokines and anaphylotoxins provided optimal catheter pore size and fluid velocity conditions

Affiliations
Free article

Microdialysis for monitoring inflammation: efficient recovery of cytokines and anaphylotoxins provided optimal catheter pore size and fluid velocity conditions

L Waelgaard et al. Scand J Immunol. 2006 Sep.
Free article

Abstract

Microdialysis emerges as a useful tool to evaluate tissue inflammation in a number of clinical conditions, like sepsis and transplant rejection, but systematic methodological studies are missing. This study was undertaken to determine the recovery of relevant inflammatory mediators using the microdialysis system, comparing microdialysis membranes with two different molecular weight cut-offs at different flow rates. Twenty and 100 kDa pore sizes CMA microdialysis catheters were investigated using velocities of 0.3, 1.0 and 5.0 microl/min. Reference preparations for cytokines [tumour necrosis factor (TNF)-alpha, interleukin (IL)-1beta, IL-6 and IL-10; m.w. 17-28 kDa] and chemokines (IL-8, MCP-1, IP-10 and MIG; m.w. 7-11 kDa) were prepared from plasma after incubating human whole blood with lipopolysaccharide. Reference preparation for complement anaphylatoxins (C3a, C4a, C5a; m.w. 9-11 kDa) was prepared by incubating human plasma with heat-aggregated immunoglobulin G. The reference preparations were quantified for the respective inflammatory molecules and used as medium for the microdialysis procedure. Through the 20 kDa filter only the four chemokines passed, but with low recovery (3-7%) and limited to the 1.0 microl/min velocity. The recovery with the 100 kDa filter was as follows: IL-1beta = 75%, MCP-1 = 55%, MIG = 50%, IL-8 = 38%, C4a = 28%, IP-10 = 22%, C5a = 20%, C3a = 16%, IL-6 = 11, IL-10 = 8% and TNF-alpha = 4%. The highest recovery for all chemokines and anaphylatoxins were consistently at velocity 1.0 microl/min, whereas IL-1beta and IL-10 recovered most efficiently at 0.3 microl/min. Thus, microdialysis using catheters with a cut-off of 100 kDa is a reliable method to detect inflammation as judged by a defined panel of inflammatory markers. These findings may have important implications for future clinical studies.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources