Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2007 Jan 17;43(2):613-8.
doi: 10.1016/j.jpba.2006.07.028. Epub 2006 Aug 22.

Simultaneous determination of sildenafil and N-desmethyl sildenafil in human plasma by high-performance liquid chromatography method using electrochemical detection with application to a pharmacokinetic study

Affiliations
Clinical Trial

Simultaneous determination of sildenafil and N-desmethyl sildenafil in human plasma by high-performance liquid chromatography method using electrochemical detection with application to a pharmacokinetic study

M Al-Ghazawi et al. J Pharm Biomed Anal. .

Abstract

A method which employed high-performance liquid chromatography coupled with electrochemical detection was developed for the simultaneous determination of sildenafil and its metabolite, N-desmethyl sildenafil, in human plasma has. The method was developed and validated for purposes of its application to a pharmacokinetic study in healthy volunteers after an oral dose of 50mg/tablet under fasting conditions. High precision and accuracy were demonstrated. A one-step liquid-liquid extraction further provides a simple and practical way to process plasma samples containing sildenafil with good quantitative recovery. Sampling lasted for 24h after dosing; consequently a limit of quantitation (LOQ) of 7.858 ng/mL was achieved for sildenafil whereas a LOQ of 8.675 ng/mL was obtained for N-desmethyl sildenafil. The mobile phase consisted of acetonitrile, methanol and phosphate buffer (0.05 M) (18.5:34.5:47.0, v/v/v) pH 7.68. The stationary phase was a C(8) (150 mm x 4.6 mm), 5 microm particle size operated at 27 degrees C. All analytes were stable at the pH of the supernatant, and during the analytical time window. At the applied potential of +1.20 V versus Ag/AgCl, no interferences from endogenous plasma compounds were recorded at the retention times of sildenafil, N-desmethyl sildenafil. High resolution was obtained between the analytes and the employed internal standards.

PubMed Disclaimer

MeSH terms

LinkOut - more resources