ReSTOR intraocular lens implantation in cataract surgery: quality of vision
- PMID: 16931256
- DOI: 10.1016/j.jcrs.2006.04.015
ReSTOR intraocular lens implantation in cataract surgery: quality of vision
Erratum in
- J Cataract Refract Surg. 2006 Dec;32(12):1987
Abstract
Purpose: To compare the visual outcome and subjective visual symptoms in patients who had implantation of the AcrySof ReSTOR multifocal intraocular lens (IOL) (Alcon Laboratories) with those in patients who received the AcrySof SA60AT monofocal IOL (Alcon Laboratories) in cataract surgery.
Setting: Southend Hospital, Essex, United Kingdom.
Methods: Eighty eyes of 40 patients received the ReSTOR multifocal IOL after cataract extraction. They were closely paired in age, sex, and ocular findings with patients who had monofocal IOL implantation during the same period. The distance and near visual acuities were compared, and patient satisfaction with their vision, visual symptoms, and spectacle dependence was assessed using a standardized questionnaire.
Results: There was no significant difference in the mean uncorrected and best corrected distance visual acuities between the groups. An uncorrected distance visual acuity of 20/30 or better was achieved in 93.8% eyes in the multifocal group and 82.5% in the monofocal group and of 20/20 or better in 57.5% and 40.0%, respectively (P = .18). Uncorrected near visual acuity was 20/30 or better in 75.0% of eyes in the multifocal group and 3.8% in the monofocal group. Reading glasses were required by 2.5% in the multifocal group and by 92.5% in the monofocal group. Satisfactory uncorrected intermediate distance vision was achieved in 75.0% of eyes in the multifocal group and 87.5% in the monofocal group (P = .089); 85.0% of patients in the multifocal group and 7.5% in the monofocal group never had to wear glasses. Moderate glare was reported by 21.3% in the multifocal group and 7.5% in the monofocal group (P = .008); no patient reported severe glare. In the multifocal group, severe halos and moderate halos occurred in 3.8% [corrected] of eyes and 16.3% [corrected] of eyes, respectively.
Conclusions: The AcrySof ReSTOR IOL provided predictably good uncorrected distance and uncorrected near acuities. Spectacle independence was significantly higher with this multifocal IOL, which outweighed the photic symptoms it caused.
Similar articles
-
Visual acuity and contrast sensitivity: AcrySof ReSTOR apodized diffractive versus AcrySof SA60AT monofocal intraocular lenses.J Cataract Refract Surg. 2007 Jul;33(7):1244-7. doi: 10.1016/j.jcrs.2007.03.052. J Cataract Refract Surg. 2007. PMID: 17586381
-
One-year outcomes with new-generation multifocal intraocular lenses.Ophthalmology. 2008 Sep;115(9):1508-16. doi: 10.1016/j.ophtha.2008.04.017. Epub 2008 Jun 5. Ophthalmology. 2008. PMID: 18538402 Clinical Trial.
-
Functional vision with bilateral ReZoom and ReSTOR intraocular lenses 6 months after cataract surgery.J Cataract Refract Surg. 2007 Dec;33(12):2057-61. doi: 10.1016/j.jcrs.2007.07.029. J Cataract Refract Surg. 2007. PMID: 18053904
-
[Multifocal intraocular lenses--an assessment of current status].Klin Monbl Augenheilkd. 1993 Jul;203(1):19-33. doi: 10.1055/s-2008-1045645. Klin Monbl Augenheilkd. 1993. PMID: 8411889 Review. German.
-
Effectiveness of multifocal and monofocal intraocular lenses for cataract surgery and lens replacement: a systematic review and meta-analysis.Graefes Arch Clin Exp Ophthalmol. 2019 May;257(5):863-875. doi: 10.1007/s00417-018-04218-6. Epub 2019 Jan 10. Graefes Arch Clin Exp Ophthalmol. 2019. PMID: 30627791
Cited by
-
Predictive factor and kappa angle analysis for visual satisfactions in patients with multifocal IOL implantation.Eye (Lond). 2011 Sep;25(9):1187-93. doi: 10.1038/eye.2011.150. Epub 2011 Jun 17. Eye (Lond). 2011. PMID: 21681216 Free PMC article.
-
Internal spherical aberration by ray tracing-type aberrometry in multifocal pseudophakic eyes.Eye (Lond). 2012 Sep;26(9):1243-8. doi: 10.1038/eye.2012.129. Epub 2012 Jun 29. Eye (Lond). 2012. PMID: 22744386 Free PMC article.
-
[Subjective and objective outcome following implantation of the apodized diffractive AcrySof ReSTOR].Ophthalmologe. 2007 May;104(5):399-404, 406-8. doi: 10.1007/s00347-007-1511-3. Ophthalmologe. 2007. PMID: 17429652 German.
-
[Bioptics with multifocal lenses and Lasek].Ophthalmologe. 2008 Sep;105(9):832-5. doi: 10.1007/s00347-008-1780-5. Ophthalmologe. 2008. PMID: 18607602 German.
-
[Apodized diffractive optic. New concept in multifocal lens technology].Ophthalmologe. 2007 Oct;104(10):899-904, 906-7. doi: 10.1007/s00347-007-1637-3. Ophthalmologe. 2007. PMID: 17978846 Review. German.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical