Fluorescence versus conventional sputum smear microscopy for tuberculosis: a systematic review
- PMID: 16931408
- DOI: 10.1016/S1473-3099(06)70578-3
Fluorescence versus conventional sputum smear microscopy for tuberculosis: a systematic review
Erratum in
- Lancet Infect Dis. 2006 Oct;6(10):628
Abstract
Most of the world's tuberculosis cases occur in low-income and middle-income countries, where sputum microscopy with a conventional light microscope is the primary method for diagnosing pulmonary tuberculosis. A major shortcoming of conventional microscopy is its relatively low sensitivity compared with culture, especially in patients co-infected with HIV. In high-income countries, fluorescence microscopy rather than conventional microscopy is the standard diagnostic method. Fluorescence microscopy is credited with increased sensitivity and lower work effort, but there is concern that specificity may be lower. We did a systematic review to summarise the accuracy of fluorescence microscopy compared with conventional microscopy. By searching many databases and contacting experts, we identified 45 relevant studies. Sensitivity, specificity, and incremental yield were the outcomes of interest. The results suggest that, overall, fluorescence microscopy is more sensitive than conventional microscopy, and has similar specificity. There is insufficient evidence to determine the value of fluorescence microscopy in HIV-infected individuals. The results of this review provide a point of reference, quantifying the potential benefit of fluorescence microscopy, with which the increased cost and technical complexity of the method can be compared to determine the possible value of the method under programme conditions.
Comment in
-
Fluorescence microscopy for tuberculosis diagnosis.Lancet Infect Dis. 2007 Apr;7(4):236-7. doi: 10.1016/S1473-3099(07)70058-0. Lancet Infect Dis. 2007. PMID: 17376374 No abstract available.
-
Fluorescence microscopy for tuberculosis diagnosis.Lancet Infect Dis. 2007 Apr;7(4):238-9; author reply 239-40. doi: 10.1016/S1473-3099(07)70059-2. Lancet Infect Dis. 2007. PMID: 17376375 No abstract available.
Similar articles
-
Commercial serological antibody detection tests for the diagnosis of pulmonary tuberculosis: a systematic review.PLoS Med. 2007 Jun;4(6):e202. doi: 10.1371/journal.pmed.0040202. PLoS Med. 2007. PMID: 17564490 Free PMC article.
-
Sputum processing methods to improve the sensitivity of smear microscopy for tuberculosis: a systematic review.Lancet Infect Dis. 2006 Oct;6(10):664-74. doi: 10.1016/S1473-3099(06)70602-8. Lancet Infect Dis. 2006. PMID: 17008175
-
Xpert MTB/RIF Ultra assay for tuberculosis disease and rifampicin resistance in children.Cochrane Database Syst Rev. 2022 Sep 6;9(9):CD013359. doi: 10.1002/14651858.CD013359.pub3. Cochrane Database Syst Rev. 2022. PMID: 36065889 Free PMC article.
-
Xpert® MTB/RIF assay for extrapulmonary tuberculosis and rifampicin resistance.Cochrane Database Syst Rev. 2018 Aug 27;8(8):CD012768. doi: 10.1002/14651858.CD012768.pub2. Cochrane Database Syst Rev. 2018. Update in: Cochrane Database Syst Rev. 2021 Jan 15;1:CD012768. doi: 10.1002/14651858.CD012768.pub3. PMID: 30148542 Free PMC article. Updated.
-
Signs and symptoms to determine if a patient presenting in primary care or hospital outpatient settings has COVID-19.Cochrane Database Syst Rev. 2022 May 20;5(5):CD013665. doi: 10.1002/14651858.CD013665.pub3. Cochrane Database Syst Rev. 2022. PMID: 35593186 Free PMC article.
Cited by
-
Evaluation of an AI-Based TB AFB Smear Screening System for Laboratory Diagnosis on Routine Practice.Sensors (Basel). 2022 Nov 4;22(21):8497. doi: 10.3390/s22218497. Sensors (Basel). 2022. PMID: 36366194 Free PMC article.
-
The implications of whole-genome sequencing in the control of tuberculosis.Ther Adv Infect Dis. 2016 Apr;3(2):47-62. doi: 10.1177/2049936115624630. Epub 2015 Dec 30. Ther Adv Infect Dis. 2016. PMID: 27034776 Free PMC article. Review.
-
Newer Diagnostic Tests for Pulmonary Tuberculosis in Children.Indian J Pediatr. 2015 Sep;82(9):827-32. doi: 10.1007/s12098-015-1848-6. Epub 2015 Jul 30. Indian J Pediatr. 2015. PMID: 26220244
-
Development and Preliminary Application of Multiplex Loop-Mediated Isothermal Amplification Coupled With Lateral Flow Biosensor for Detection of Mycobacterium tuberculosis Complex.Front Cell Infect Microbiol. 2021 Apr 27;11:666492. doi: 10.3389/fcimb.2021.666492. eCollection 2021. Front Cell Infect Microbiol. 2021. PMID: 33987108 Free PMC article.
-
Strengthening health systems to improve the value of tuberculosis diagnostics in South Africa: A cost and cost-effectiveness analysis.PLoS One. 2021 May 14;16(5):e0251547. doi: 10.1371/journal.pone.0251547. eCollection 2021. PLoS One. 2021. PMID: 33989317 Free PMC article.