Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2006 Sep;103(3):540-4.
doi: 10.1213/01.ane.0000226098.95698.0f.

Bivalirudin provides rapid, effective, and reliable anticoagulation during off-pump coronary revascularization: results of the "EVOLUTION OFF" trial

Affiliations
Clinical Trial

Bivalirudin provides rapid, effective, and reliable anticoagulation during off-pump coronary revascularization: results of the "EVOLUTION OFF" trial

Andreas Koster et al. Anesth Analg. 2006 Sep.

Abstract

In the EVOLUTION OFF trial, we evaluated the safety and efficacy of bivalirudin during off-pump coronary artery bypass grafting as compared with heparin-protamine. In this subanalysis of EVOLUTION OFF data of bivalirudin-treated patients, we assessed the pharmacokinetics (PK) and effectiveness of bivalirudin anticoagulation to achieve target activated clotting time (ACT)+ values. Data from 101 patients were assessed. A bolus of 0.75 mg/kg of bivalirudin was followed by a continuous infusion of 1.75 mg x kg(-1) x h(-1) during the grafting procedure. An ACT+ value of >300 s was the target. In four patients, PK data for bivalirudin were obtained. Only in exceptional cases were repeat fractional boluses or an increase of the infusion rate required. Assessment of the PK data showed a mean concentration of bivalirudin after the initial bolus of 11.0 +/- 0.53 microg/mL and a mean concentration during infusion of 11.2 +/- 2.32 microg/mL. Pearson's correlation between bivalirudin concentrations and ACT+ values was 0.92. Bivalirudin PK data consistently exceeded concentrations of 6.5 microg/mL, which have been evaluated as effective during percutaneous coronary intervention. The correlation between bivalirudin levels and ACT+ values was good, and the target ACT+ values were almost always achieved. These results suggest that bivalirudin, given according to the current protocol, provides reliable and effective anticoagulation during off-pump coronary artery bypass graft surgery.

PubMed Disclaimer

Publication types