Mesh augmentation during pelvic-floor reconstructive surgery: risks and benefits
- PMID: 16932053
- DOI: 10.1097/01.gco.0000242961.48114.b0
Mesh augmentation during pelvic-floor reconstructive surgery: risks and benefits
Abstract
Purpose of review: Synthetic meshes are increasingly used in the surgical management of stress urinary incontinence and pelvic-organ prolapse in an attempt to improve success rates and increase the longevity of repairs. This review describes and analyses complications following pelvic-floor procedures employing synthetic meshes.
Recent findings: Type I monofilament polypropylene mesh with a large pore size is currently the mesh of choice. Chronic inflammation is a typical host response, whereas acute inflammation and predominant CD20+ lymphocyte infiltration represent an adverse host reaction and may result in defective healing. Mesh properties influence the performance and complication rate. Mesh-related complications after midurethral slings and mesh sacrocolpopexies with monofilament polypropylene are rare. An up to 26% mesh erosion rate and up to 38% dyspareunia rate with vaginally introduced mesh for pelvic-organ prolapse repair has been reported. Concurrent hysterectomy seems to increase mesh erosion rates.
Summary: Surgeons should be aware of the potential complications of synthetic meshes. Until data on the safety and efficacy of synthetic mesh in vaginal reconstructive surgery emerge, its routine use outside of clinical trials cannot be recommended.
Similar articles
-
Mesh-related infections after pelvic organ prolapse repair surgery.Eur J Obstet Gynecol Reprod Biol. 2007 Oct;134(2):147-56. doi: 10.1016/j.ejogrb.2007.02.024. Epub 2007 Apr 24. Eur J Obstet Gynecol Reprod Biol. 2007. PMID: 17459563 Review.
-
[Management of selected complications following urogynecological surgeries with the use of synthetic prostheses--own observations].Ginekol Pol. 2008 Aug;79(8):550-4. Ginekol Pol. 2008. PMID: 18819463 Polish.
-
The use of prosthetics in pelvic reconstructive surgery.Best Pract Res Clin Obstet Gynaecol. 2005 Dec;19(6):979-91. doi: 10.1016/j.bpobgyn.2005.08.013. Epub 2005 Sep 26. Best Pract Res Clin Obstet Gynaecol. 2005. PMID: 16185932 Review.
-
Severe mesh complications following intravaginal slingplasty.Obstet Gynecol. 2005 Oct;106(4):713-6. doi: 10.1097/01.AOG.0000177970.52037.0a. Obstet Gynecol. 2005. PMID: 16199626
-
[Development of better tolerated prosthetic materials: applications in gynecological surgery].J Gynecol Obstet Biol Reprod (Paris). 2002 Oct;31(6):527-40. J Gynecol Obstet Biol Reprod (Paris). 2002. PMID: 12407323 Review. French.
Cited by
-
Complications of grafts used in female pelvic floor reconstruction: Mesh erosion and extrusion.Indian J Urol. 2007 Apr;23(2):153-60. doi: 10.4103/0970-1591.32067. Indian J Urol. 2007. PMID: 19675793 Free PMC article.
-
Management of vaginal mesh exposure: A systematic review.Arab J Urol. 2019 Apr 4;17(1):40-48. doi: 10.1080/2090598X.2019.1589787. eCollection 2019 Mar. Arab J Urol. 2019. PMID: 31258942 Free PMC article. Review.
-
Transverse cystocele repair with uterine preservation using native tissue.Int Urogynecol J Pelvic Floor Dysfunct. 2008 Sep;19(9):1275-81. doi: 10.1007/s00192-008-0629-4. Epub 2008 May 8. Int Urogynecol J Pelvic Floor Dysfunct. 2008. PMID: 18463776
-
Efficacy of anchoring the four-arm transvaginal mesh to the mid-urethra vs original surgery as a surgical correction for stress urine incontinence in coexisting anterior vaginal prolapse grades II and III: study protocol for a randomized controlled trial.Trials. 2017 Dec 28;18(1):624. doi: 10.1186/s13063-017-2314-8. Trials. 2017. PMID: 29282115 Free PMC article.
-
Prolapse repair using the Elevate™ kit: prospective study on 70 patients.Int Urogynecol J. 2012 Oct;23(10):1421-8. doi: 10.1007/s00192-012-1673-7. Epub 2012 Mar 1. Int Urogynecol J. 2012. PMID: 22382654
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Research Materials