Filtering techniques for the removal of ventilator artefact in oesophageal pulse oximetry
Abstract
The oesophagus has been shown to be a reliable site for monitoring blood oxygen saturation (SpO(2)). However, the photoplethysmographic (PPG) signals from the lower oesophagus are frequently contaminated by a ventilator artefact making the estimation of SpO(2) impossible. A 776th order finite impulse response (FIR) filter and a 695th order interpolated finite impulse response (IFIR) filter were implemented to suppress the artefact. Both filters attenuated the ventilator artefact satisfactorily without distorting the morphology of the PPG when processing recorded data from ten cardiopulmonary bypass patients. The IFIR filter was the better since it conformed more closely to the desired filter specifications and allowed real-time processing. The average improvements in signal-to-noise ratio (SNR) achieved by the FIR and IFIR filters for the fundamental component of the red PPG signals with respect to the fundamental component of the artefact were 57.96 and 60.60 dB, respectively. The corresponding average improvements achieved by the FIR and IFIR filters for the infrared PPG signals were 54.83 and 60.96 dB, respectively. Both filters were also compared with their equivalent tenth order Butterworth filters. The average SNR improvements for the FIR and IFIR filters were significantly higher than those for the Butterworth filters.
Similar articles
-
In vivo investigation of ear canal pulse oximetry during hypothermia.J Clin Monit Comput. 2018 Feb;32(1):97-107. doi: 10.1007/s10877-017-9975-4. Epub 2017 Jan 27. J Clin Monit Comput. 2018. PMID: 28130679 Free PMC article.
-
Investigation of oesophageal photoplethysmographic signals and blood oxygen saturation measurements in cardiothoracic surgery patients.Physiol Meas. 2002 Aug;23(3):533-45. doi: 10.1088/0967-3334/23/3/305. Physiol Meas. 2002. PMID: 12214761
-
Evaluation of oesophageal reflectance pulse oximetry in major burns patients.Burns. 2005 May;31(3):337-41. doi: 10.1016/j.burns.2004.10.025. Epub 2005 Jan 20. Burns. 2005. PMID: 15774290
-
Pulse oximetry in the oesophagus.Physiol Meas. 2006 Jan;27(1):R1-35. doi: 10.1088/0967-3334/27/1/R01. Epub 2005 Nov 29. Physiol Meas. 2006. PMID: 16365505 Review.
-
Pulse oximetry and photoplethysmographic waveform analysis of the esophagus and bowel.Curr Opin Anaesthesiol. 2008 Dec;21(6):779-83. doi: 10.1097/ACO.0b013e328317794d. Curr Opin Anaesthesiol. 2008. PMID: 18997529 Review.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous