Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2006 Sep;40(8):705-10.
doi: 10.1097/00004836-200609000-00009.

Value of adenosine deaminase (ADA) in ascitic fluid for the diagnosis of tuberculous peritonitis: a meta-analysis

Affiliations
Meta-Analysis

Value of adenosine deaminase (ADA) in ascitic fluid for the diagnosis of tuberculous peritonitis: a meta-analysis

Arnoldo Riquelme et al. J Clin Gastroenterol. 2006 Sep.

Abstract

Background and goals: Adenosine deaminase (ADA) levels are used for diagnosing tuberculosis in several locations and although many studies have evaluated ADA levels in ascitic fluid. These studies have defined arbitrary cut-off points creating difficulties in the clinical application of the results. The goals of this study are: to determine the usefulness of ADA levels in ascitic fluid as a diagnostic test for peritoneal tuberculosis (PTB) and define the best cut-off point.

Study: A systematic review was done on the basis of 2 independent searches. We selected prospective studies that included consecutive patients. Diagnosis of PTB had to be confirmed by bacteriologic or histologic methods and ADA levels determined by the Giusti method. Inclusion/exclusion criteria were applied by 2 independent reviewers. A receiver operating characteristic curve was constructed to establish the optimal cut-off point and the likelihood ratios (LRs) estimated using fixed-effect pooled method.

Results: Twelve prospective studies were found. Four of them met the inclusion criteria and were thus included in the meta-analysis. They included 264 patients, of which 50 (18.9%) had PTB. ADA levels showed high sensitivity (100%) and specificity (97%) using cut-off values from 36 to 40 IU/L. The included studies were homogeneous. Optimal cut-off point was determined at 39 IU/L, and LRs were 26.8 and 0.038 for values above and below this cut-off.

Conclusions: This study supports the proposition that ADA determination is a fast and discriminating test for diagnosing PTB with an optimal cut-off value of 39 IU/L.