. 2006 Oct;32(10):1584-90.
doi: 10.1007/s00134-006-0357-5. Epub 2006 Aug 29.

Does PEEP impair the hepatic outflow in patients following liver transplantation?

Affiliations

Does PEEP impair the hepatic outflow in patients following liver transplantation?

Fuat H Saner et al. Intensive Care Med. 2006 Oct.

Abstract

Objective: Evaluation of the impact of end-expiratory pressure (PEEP) ventilation on venous liver outflow, portal vein, and hepatic artery flows as well as systemic hemodynamics in patients following liver transplantation (LT).

Design: Prospective, interventional patient study.

Setting: University hospital intensive care unit.

Patients: 65 consecutive patients after LT.

Interventions: All patients were intubated and mechanically ventilated with biphasic positive airway pressure (BIPAP). The effects of three levels of PEEP (0, 5, and 10 mbar) applied at random order on hepatic inflow and outflow were studied in the immediate postoperative period.

Measurement and results: Central venous-, arterial pressure, and cardiac index was recorded from every patient at three different PEEP levels (0, 5, and 10 mbar). Simultaneously, flow velocities in the hepatic-, portal vein, and hepatic artery were determined by Doppler ultrasound. PEEP of 10 mbar significantly increased central venous pressure in comparison with zero PEEP. Mean arterial pressure and cardiac index was not influenced. Hepatic inflow and outflow of the transplanted livers were not impaired by any of the used PEEP levels.

Conclusions: BIPAP ventilation with PEEP levels up to 10 mbar does not affect systemic hemodynamics. Furthermore, neither venous outflow nor portal venous or hepatic artery inflow of the liver are impaired at PEEP levels up to 10 mbar immediately following liver transplantation. Although these results suggest that PEEP ventilation up to 10 mbar does not affect liver hemodynamics, further studies are needed to determine whether these findings could be confirmed for a longer ventilation period with PEEP.

PubMed Disclaimer

Comment in

References

    1. Chest. 2001 Jan;119(1):219-23 - PubMed
    1. Radiology. 1990 Sep;176(3):655-8 - PubMed
    1. J Hepatol. 1995 Jun;22(6):623-32 - PubMed
    1. Am J Respir Crit Care Med. 1998 Apr;157(4 Pt 1):1219-25 - PubMed
    1. Ann Surg. 1983 Aug;198(2):218-22 - PubMed

LinkOut - more resources