Measurement of single kidney function using dynamic contrast-enhanced MRI: comparison of two models in human subjects

Affiliations
Comparative Study

Measurement of single kidney function using dynamic contrast-enhanced MRI: comparison of two models in human subjects

David L Buckley et al. J Magn Reson Imaging. 2006 Nov.

Abstract

Purpose: To compare two methods for assessing the single kidney glomerular filtration rate (SK-GFR) in humans using dynamic contrast-enhanced (DCE)-MRI.

Materials and methods: Images were acquired from 39 separate MR studies of patients with atherosclerotic renovascular disease (ARVD). Data from the kidneys and descending aorta were analyzed using both a Rutland-Patlak plot and a compartmental model. MR estimates of the SK-GFR were compared with standard radioisotope measures in a total of 75 kidneys.

Results: Estimates of renal function using both techniques correlated well with radioisotope-assessed SK-GFR (Spearman's rho=0.81, Rutland-Patlak; rho=0.71, compartmental model). The Rutland-Patlak approach provided a near one-to-one correspondence, while the compartmental method tended to overestimate SK-GFR. However, the compartmental model fits to the experimental data were significantly better than those obtained using the Rutland-Patlak approach.

Conclusion: DCE-MRI of the kidneys provides data that correlate well with reference measures of SK-GFR. However, further work, including image registration, is needed to isolate measurement of glomerular filtration to the level of the renal cortex.