Double jeopardy: balance between bleeding and stent thrombosis with prolonged dual antiplatelet therapy after drug-eluting stent implantation
- PMID: 16945822
- DOI: 10.1016/j.carrev.2006.04.001
Double jeopardy: balance between bleeding and stent thrombosis with prolonged dual antiplatelet therapy after drug-eluting stent implantation
Abstract
Prolonged dual antiplatelet therapy with aspirin and clopidogrel is mandatory after drug-eluting stent (DES) implantation because of potential increase risk of stent thrombosis compared to bare-metal stents. As more DES are being implanted, many of these patients will undergo non-cardiac surgery whilst on antiplatelet therapy. The optimal management of perioperative antiplatelet therapy is not well established. The risk of excessive bleeding associated with antiplatelet therapy needs to be balanced against the risk of stent thrombosis with interruption of antiplatelet therapy on a case-to-case basis.
Similar articles
-
Frequency of and risk factors for stent thrombosis after drug-eluting stent implantation during long-term follow-up.Am J Cardiol. 2006 Aug 1;98(3):352-6. doi: 10.1016/j.amjcard.2006.02.039. Epub 2006 Jun 12. Am J Cardiol. 2006. PMID: 16860022
-
Observance of antiplatelet therapy after stent implantation in patients under chronic oral anticoagulant treatment.J Interv Cardiol. 2008 Jun;21(3):218-24. doi: 10.1111/j.1540-8183.2008.00354.x. Epub 2008 Apr 17. J Interv Cardiol. 2008. PMID: 18422520
-
[Optimal platelet inhibition after coronary stent implantation. Current status].Herz. 2008 Jun;33(4):244-53. doi: 10.1007/s00059-008-3138-9. Herz. 2008. PMID: 18581073 Review. German.
-
Effectiveness of two-year clopidogrel + aspirin in abolishing the risk of very late thrombosis after drug-eluting stent implantation (from the TYCOON [two-year ClOpidOgrel need] study).Am J Cardiol. 2009 Nov 15;104(10):1357-61. doi: 10.1016/j.amjcard.2009.07.002. Epub 2009 Sep 26. Am J Cardiol. 2009. PMID: 19892050
-
Significant gastrointestinal bleeding in patients at risk of coronary stent thrombosis.Rev Cardiovasc Med. 2009 Winter;10(1):14-24. Rev Cardiovasc Med. 2009. PMID: 19367228 Review.
Cited by
-
Biocompatibility of Coronary Stents.Materials (Basel). 2014 Jan 28;7(2):769-786. doi: 10.3390/ma7020769. Materials (Basel). 2014. PMID: 28788487 Free PMC article. Review.
-
[Bedside thrombelastography. Cost reduction in cardiac surgery].Anaesthesist. 2007 Aug;56(8):765-71. doi: 10.1007/s00101-007-1200-2. Anaesthesist. 2007. PMID: 17516038 German.
-
Two-year clinical outcomes after large coronary stent (4.0 mm) placement: comparison of bare-metal stent versus drug-eluting stent.Clin Cardiol. 2010 Oct;33(10):620-625. doi: 10.1002/clc.20781. Clin Cardiol. 2010. PMID: 20960536 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Research Materials