Use of a flow-mediated vasodilation technique to assess endothelial function in dogs
- PMID: 16948597
- DOI: 10.2460/ajvr.67.9.1533
Use of a flow-mediated vasodilation technique to assess endothelial function in dogs
Abstract
Objective: To develop and assess the reproducibility of a protocol to noninvasively test endothelial function in dogs on the basis of the flow-mediated vasodilation (FMD) procedure used in humans.
Animals: 5 healthy spayed female dogs.
Procedures: Luminal arterial diameter and blood flow velocity in the brachial and femoral arteries were measured with ultrasonography. The within-dog reproducibility of these ultrasonographic measurements was tested. An occlusion period of 1, 3, or 5 minutes with an inflatable cuff was used to create the FMD response. Measurements made at 15, 30, and 60 seconds following release of the occlusion were compared with measurements made immediately prior to each occlusion to assess the FMD response.
Results: Within-dog reproducibility of measurements revealed moderate to high correlations. Change from baseline in luminal arterial diameter was most substantial when measured at 30 seconds following release of occlusion, whereas blood flow velocity changes were maximal when measured at 15 seconds following release. The brachial imaging site provided a larger number of significant FMD responses than the femoral site. The 3-minute occlusion period provided equal or better responses than the 5-minute occlusion period.
Conclusions and clinical relevance: Ultrasonographic measurement of the FMD responses was a feasible and reproducible technique and significant changes from baseline were detected. The FMD responses in dogs were most substantial when performed at the brachial artery with blood flow velocity and luminal arterial diameter changes from baseline measured at 15 and 30 seconds, respectively, following release of a 3-minute occlusion period.
Similar articles
-
Comparison of flow-mediated vasodilation in femoral and brachial arteries in healthy dogs.Am J Vet Res. 2011 Aug;72(8):1029-37. doi: 10.2460/ajvr.72.8.1029. Am J Vet Res. 2011. PMID: 21801059
-
Evaluation of a flow-mediated vasodilation measurement technique in healthy dogs.Am J Vet Res. 2010 Oct;71(10):1154-61. doi: 10.2460/ajvr.71.10.1154. Am J Vet Res. 2010. PMID: 20919901
-
Occlusion cuff position is an important determinant of the time course and magnitude of human brachial artery flow-mediated dilation.Clin Sci (Lond). 2000 Oct;99(4):261-7. Clin Sci (Lond). 2000. PMID: 10995590 Clinical Trial.
-
Detection of endothelial dysfunction with brachial artery ultrasound scanning.Am Heart J. 2003 Jun;145(6):943-51. doi: 10.1016/S0002-8703(03)00097-8. Am Heart J. 2003. PMID: 12796748 Review.
-
Assessment of flow-mediated vasodilatation (FMD) of the brachial artery: effects of technical aspects of the FMD measurement on the FMD response.Eur Heart J. 2005 Feb;26(4):363-8. doi: 10.1093/eurheartj/ehi017. Epub 2004 Dec 1. Eur Heart J. 2005. PMID: 15618057 Review.
Cited by
-
Noninvasive assessment of pulse-wave velocity and flow-mediated vasodilation in anesthetized Göttingen minipigs.Comp Med. 2014 Dec;64(6):471-7. Comp Med. 2014. PMID: 25527028 Free PMC article.
-
Circulating hyaluronan as a marker of endothelial glycocalyx damage in dogs with myxomatous mitral valve disease and dogs in a hypercoagulable state.Vet J. 2022 Jul;285:105845. doi: 10.1016/j.tvjl.2022.105845. Epub 2022 May 28. Vet J. 2022. PMID: 35640794 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources