Role of biplane and biplane echocardiographically guided 3-dimensional echocardiography during dobutamine stress echocardiography
- PMID: 16950468
- DOI: 10.1016/j.echo.2006.04.016
Role of biplane and biplane echocardiographically guided 3-dimensional echocardiography during dobutamine stress echocardiography
Abstract
Image acquisition time and wall-motion score of conventional 2-dimensional (2D) dobutamine stress echocardiography (DSE) were compared with those of biplane and 3-dimensional (3D) DSE in 50 patients (age 67 +/- 13 years) with regular rhythms during clinically indicated DSE. Commercially available systems were used for the study. We used a conventional transducer for 2D and a matrix-array transducer (x4 or x3-1) for two biplane (60- and 120-degree) images and one 3D full-volume image. Image quality was scored as 1 = good; 2 = adequate; and 3 = inadequate. Segmental wall-motion scores for each method were analyzed in blinded fashion. Acquisition times of biplane (9.3 +/- 2.8 seconds) and biplane-guided 3D (additional 2.6 +/- 1.0 seconds) echocardiography were significantly shorter than those of conventional 2D DSE (60.0 +/- 26.7 seconds) (P < .001). Image quality was adequate or good in 94% for biplane and 96% for 3D echocardiography. Agreement of segmental wall-motion score was present in 87.6% of segments for 2D versus biplane and 85.9% for 2D versus 3D at baseline and in 88.0% for 2D versus biplane and 87.4% for 2D versus 3D at peak stress. Acquisition of biplane or biplane-guided 3D volumetric data during DSE with use of a new matrix-array transducer was feasible and shortened image acquisition time without affecting the diagnostic yield compared with conventional 2D imaging.
Similar articles
-
Comparison of contrast-enhanced real-time live 3-dimensional dobutamine stress echocardiography with contrast 2-dimensional echocardiography for detecting stress-induced wall-motion abnormalities.J Am Soc Echocardiogr. 2006 Mar;19(3):294-9. doi: 10.1016/j.echo.2005.10.008. J Am Soc Echocardiogr. 2006. PMID: 16500492 Clinical Trial.
-
Assessment of image quality in real time three-dimensional dobutamine stress echocardiography: an integrated 2D/3D approach.Echocardiography. 2015 Mar;32(3):496-507. doi: 10.1111/echo.12692. Epub 2014 Jul 24. Echocardiography. 2015. PMID: 25059625
-
Non-invasive assessment of myocardial ischaemia using new real-time three-dimensional dobutamine stress echocardiography: comparison with conventional two-dimensional methods.Eur Heart J. 2005 Aug;26(16):1625-32. doi: 10.1093/eurheartj/ehi194. Epub 2005 Apr 7. Eur Heart J. 2005. PMID: 15817607
-
Real time three-dimensional stress echocardiography advantages and limitations.Echocardiography. 2012 Feb;29(2):200-6. doi: 10.1111/j.1540-8175.2011.01626.x. Echocardiography. 2012. PMID: 22283201 Review.
-
Three-dimensional echocardiography in evaluation of left ventricular indices.Echocardiography. 2012;29(1):66-75. doi: 10.1111/j.1540-8175.2011.01526.x. Echocardiography. 2012. PMID: 23186291 Review.
Cited by
-
Three-dimensional echocardiography in adult congenital heart disease.Korean J Intern Med. 2017 Jul;32(4):577-588. doi: 10.3904/kjim.2016.251. Epub 2017 Jun 30. Korean J Intern Med. 2017. PMID: 28704916 Free PMC article. Review.
-
Initial experience using contrast enhanced real-time three-dimensional exercise stress echocardiography in a low-risk population.Heart Int. 2010 Jun 23;5(1):e8. doi: 10.4081/hi.2010.e8. Heart Int. 2010. PMID: 21977293 Free PMC article.
-
The role of stress echocardiography in the evaluation of coronary artery disease and myocardial ischemia in women.J Nucl Cardiol. 2016 Oct;23(5):1023-1035. doi: 10.1007/s12350-016-0592-2. Epub 2016 Jul 25. J Nucl Cardiol. 2016. PMID: 27457525 Review.
-
Vascular imaging in diabetes.Curr Atheroscler Rep. 2014 Apr;16(4):399. doi: 10.1007/s11883-014-0399-z. Curr Atheroscler Rep. 2014. PMID: 24493479 Review.
-
Stress echocardiography for the detection and assessment of coronary artery disease.J Nucl Cardiol. 2011 May;18(3):501-15. doi: 10.1007/s12350-011-9365-0. J Nucl Cardiol. 2011. PMID: 21431999 Review. No abstract available.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources