Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1990 Aug;9(8):2447-51.
doi: 10.1002/j.1460-2075.1990.tb07421.x.

Transients of perforin pore formation observed by fluorescence microscopic single channel recording

Affiliations

Transients of perforin pore formation observed by fluorescence microscopic single channel recording

R Peters et al. EMBO J. 1990 Aug.

Abstract

A new type of single channel recording is described. Large pores were generated in the membranes of resealed human erythrocyte ghosts by incubation with perforin (cytolysin). The flux of the polar fluorescent probe Lucifer Yellow was measured in single ghosts by the fluorescence microphotolysis (photobleaching) technique. The distribution of flux rates for ghosts treated with a limiting perforin concentration showed equidistantly spaced peaks suggesting that subpopulations of ghosts with 0, 1 and 2 pores were resolved. Furthermore, distributions obtained for very different perforin concentrations could be well simulated by using one common value for the flux rate of the single pore (k = 4.65 x 10(-3) s) and assuming a Poisson distribution of pores among ghosts. The flux rate of the single pore corresponds to a pore radius of approximately 50 A, a value which is much smaller than that obtained previously by electron microscopic studies but which agrees well with recent electrical single channel recordings. Mature perforin pores were observed to be very stable. No closing events were detected at a time resolution of 0.2 s for a wide range of temperatures and Ca2+ concentrations. However, the formation of new pores was an unexpectedly slow process. Fluorescence microscopic single channel recording as introduced by this study is applicable to a variety of cellular systems and fluorescent probes and thus may complement the information obtainable by electrical single channel recording of anorganic ion fluxes.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Biol Chem. 1985 Aug 5;260(16):9069-72 - PubMed
    1. J Exp Med. 1987 May 1;165(5):1371-82 - PubMed
    1. J Biol Chem. 1983 Oct 10;258(19):11427-9 - PubMed
    1. J Exp Med. 1983 May 1;157(5):1483-95 - PubMed
    1. Nature. 1980 Oct 2;287(5781):447-9 - PubMed

Publication types