[Growth and detection of aerobic bacterial pathogens in BacT/Alert FA, BacT/Alert SA, Bactec Plus Aerobic/F and Bactec Standard Aerobic/F]
- PMID: 16958021
[Growth and detection of aerobic bacterial pathogens in BacT/Alert FA, BacT/Alert SA, Bactec Plus Aerobic/F and Bactec Standard Aerobic/F]
Abstract
The article compares the ability of detection and detection times (TTD) of aerobic bacteria in the BacT/Alert FA, BacT/Alert SA, Bactec Plus Aerobic/F and Bactec Standard Aerobic/F bottles. Compared bottles were inoculated at the same time with the identical suspension of bacterial strain. All bottles detected bacterial pathogens even in the case of very low number of inoculated bacteria. The differences of TTD were detected between the bottles of compared hemocultivation systems. Bactec Plus Aerobic/F system is faster in the detection of the members of family Enterobacteriaceae at 1-3 hours, BacT/Aert FA system is faster in the detection of coagulase-negative staphylococci. Most difference was detected at Pseudomanas stutzeri, where the detection in BacT/Alert FA bottles was at 15 hours faster in opposite of Bactec Plus Aerobic/F bottles. In the bottles without sorbent Staphylococcus aureus and Streptococcus sanqui were detected faster in the system Bactec Standard Aerobic/F. The bottles BacT/Alert SA detected faster skin corynebacteria. Detected differences have not a practical importance for the blood stream infection diagnostics.
Similar articles
-
[Comparison of the detection of anaerobic bacteria in haemoculture systems BACTEC Lytic/10 Anaerobic/F, BacT/Alert FAN Anaerobic and BacT/Alert FN Anaerobic].Klin Mikrobiol Infekc Lek. 2005 Jun;11(3):100-4. Klin Mikrobiol Infekc Lek. 2005. PMID: 16025428 Czech.
-
Comparison of BACTEC PLUS blood culture media to BacT/Alert FA blood culture media for detection of bacterial pathogens in samples containing therapeutic levels of antibiotics.J Clin Microbiol. 2007 Mar;45(3):816-21. doi: 10.1128/JCM.02064-06. Epub 2006 Dec 13. J Clin Microbiol. 2007. PMID: 17166960 Free PMC article.
-
Comparison of the BACTEC MYCO/F Lytic bottle to the isolator tube, BACTEC Plus Aerobic F/bottle, and BACTEC Anaerobic Lytic/10 bottle and comparison of the BACTEC Plus Aerobic F/bottle to the Isolator tube for recovery of bacteria, mycobacteria, and fungi from blood.J Clin Microbiol. 2001 Dec;39(12):4380-6. doi: 10.1128/JCM.39.12.4380-4386.2001. J Clin Microbiol. 2001. PMID: 11724848 Free PMC article.
-
[Culture based diagnostic methods for tuberculosis].Mikrobiyol Bul. 2005 Jan;39(1):107-24. Mikrobiyol Bul. 2005. PMID: 15900845 Review. Turkish.
-
[Blood culture update].Presse Med. 2002 Jan 12;31(1 Pt 1):27-32. Presse Med. 2002. PMID: 11826583 Review. French.
Publication types
MeSH terms
Substances
LinkOut - more resources
Research Materials