[Image-guided radiotherapy by in-room CT-linear accelerator combination]
- PMID: 16959518
- DOI: 10.1016/j.canrad.2006.06.004
[Image-guided radiotherapy by in-room CT-linear accelerator combination]
Abstract
Target localization has become increasingly important in the advent of IMRT, as treatment margins are reduced and target doses are increased with high-dose gradients outside this target volume. The in-room CT on rails-LINAC system allows CT imaging while the patient remains immobilized in the treatment position just prior to treatment. The anatomic inter- and intra-fractional variations can be therefore quantified during a course of treatment. The position of the tumour can be checked and corrected before the fraction. In case of modification of tumour shape, a re-planning of the treatment is also feasible. However, several issues remain: the integration with routine clinical treatment due to a lack of software tools, the frequency of imaging, and the cost-efficiency ratio. The clinical experience is yet very limited but CT-image-guided radiotherapy appears promising for prostate, brain and spinal tumours.
Similar articles
-
Application of dose compensation in image-guided radiotherapy of prostate cancer.Phys Med Biol. 2006 Mar 21;51(6):1405-19. doi: 10.1088/0031-9155/51/6/003. Epub 2006 Feb 21. Phys Med Biol. 2006. PMID: 16510952
-
[Megavoltage cone-beam CT: Recent developments and clinical applications].Cancer Radiother. 2006 Sep;10(5):258-68. doi: 10.1016/j.canrad.2006.05.010. Epub 2006 Jul 24. Cancer Radiother. 2006. PMID: 16861025 French.
-
Optimal control of set-up margins and internal margins for intra- and extracranial radiotherapy using stereoscopic kilovoltage imaging.Cancer Radiother. 2006 Sep;10(5):235-44. doi: 10.1016/j.canrad.2006.05.011. Epub 2006 Jul 18. Cancer Radiother. 2006. PMID: 16854609 Review.
-
In-room CT techniques for image-guided radiation therapy.Med Dosim. 2006 Spring;31(1):30-9. doi: 10.1016/j.meddos.2005.12.010. Med Dosim. 2006. PMID: 16551527 Review.
-
Image-guided radiotherapy using megavoltage cone-beam computed tomography for treatment of paraspinous tumors in the presence of orthopedic hardware.Int J Radiat Oncol Biol Phys. 2006 Oct 1;66(2):323-6. doi: 10.1016/j.ijrobp.2006.05.038. Int J Radiat Oncol Biol Phys. 2006. PMID: 16965986
Cited by
-
Intrafraction motion of the prostate during an IMRT session: a fiducial-based 3D measurement with Cone-beam CT.Radiat Oncol. 2008 Nov 5;3:37. doi: 10.1186/1748-717X-3-37. Radiat Oncol. 2008. PMID: 18986517 Free PMC article.
-
Contemporary management of high-risk localized prostate cancer.Curr Urol Rep. 2010 May;11(3):159-64. doi: 10.1007/s11934-010-0101-0. Curr Urol Rep. 2010. PMID: 20425622 Review.
-
Image guidance in radiation therapy: techniques and applications.Radiol Res Pract. 2014;2014:705604. doi: 10.1155/2014/705604. Epub 2014 Dec 17. Radiol Res Pract. 2014. PMID: 25587445 Free PMC article. Review.
-
Current concepts on imaging in radiotherapy.Eur J Nucl Med Mol Imaging. 2008 Apr;35(4):821-37. doi: 10.1007/s00259-007-0631-y. Epub 2007 Oct 31. Eur J Nucl Med Mol Imaging. 2008. PMID: 17972074
-
Influence of acquisition parameters on MV-CBCT image quality.J Appl Clin Med Phys. 2012 Jan 5;13(1):3638. doi: 10.1120/jacmp.v13i1.3638. J Appl Clin Med Phys. 2012. PMID: 22231215 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical