Evaporative tunnel cooling of dairy cows in the southeast. I: effect on body temperature and respiration rate

Affiliations
Free article
Comparative Study

Evaporative tunnel cooling of dairy cows in the southeast. I: effect on body temperature and respiration rate

T R Smith et al. J Dairy Sci. 2006 Oct.
Free article

Abstract

The techniques used to mitigate the effects of heat stress on lactating dairy cows are often overwhelmed in the southeastern United States, where elevated heat and humidity often persist for extended periods. A model free-stall barn located at the North Mississippi Branch Experiment Station in Holly Springs was used to evaluate the potential of tunnel ventilation with evaporative cooling to alleviate heat stress in lactating dairy cows. Two studies were conducted using 2 groups of 10 lactating Holsteins housed in the tunnel barn (inside) and 2 groups of matched herdmates housed in an adjacent covered free-stall barn (outside), which was cooled by fans and sprinklers during 2001 or by shade and fans alone in 2003. Peak daytime temperatures inside were 5.2 +/- 0.18 degrees C below that outside in 2001 and 3.1 +/- 0.20 degrees C lower in 2003. Although evaporative cooling increased humidity by 22%, cows housed in the tunnel barn received 84% less exposure to moderate heat stress (temperature-humidity index > 80) in both years. Cooling cows with evaporative tunnel ventilation reduced respiration rates by 15.5 +/- 0.56 breaths/min and rectal temperatures by 0.6 +/- 0.02 degrees C compared with shade and fans alone in 2003. Cooling cows with evaporative tunnel ventilation reduced respiration rates by 13.1 +/- 0.78 breaths/min and rectal temperatures by 0.4 +/- 0.03 degrees C compared with fans and sprinklers in 2001. Thus, tunnel ventilation cooling dramatically reduced the exposure to heat stress and improved the comfort of lactating dairy cows when compared with traditional cooling technologies under the conditions present in the southeastern United States.