Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Oct;16(4):763-9.

99mTc-tetrofosmin SPECT in solitary pulmonary nodule evaluation

Affiliations
  • PMID: 16969491

99mTc-tetrofosmin SPECT in solitary pulmonary nodule evaluation

Angela Spanu et al. Oncol Rep. 2006 Oct.

Abstract

A correct differential diagnosis between benign and malignant lesions is mandatory in patients with solitary pulmonary nodule (SPN). The aim of the present study was to investigate whether 99mTc-tetrofosmin SPECT may play a role in SPN evaluation. A consecutive series of 111 patients with an uncalcified </=3 cm (range: 0.8-3 cm) SPN, without definite benign findings and indeterminate at CT, were studied. Within 1 week of CT scan, following 740 MBq of 99mTc-tetrofosmin i.v. injection, all patients underwent chest SPECT using a rectangular dual head gamma camera with HR collimators. The images were analysed both qualitatively and semiquantitatively by calculating tumor/normal tissue ratio (T/N). All nodules were referred to a definitive diagnosis after scintigraphy: 84/111 nodules resulted malignant (primary lung carcinomas in 59 cases and metastases in 25), whereas 27/111 were benign. SPECT was true positive in 77/84 malignant nodules (overall sensitivity: 91.7%), detecting 55/59 carcinomas (93.2%) and 22/25 metastases (88%), whereas it was false negative in 4 carcinomas (3 adenocarcinomas and 1 squamous cell carcinoma, the latter with necrotic areas; range size: 1.5-2.4 cm) and in 3 metastases (range size: 1.0-1.2 cm). SPECT was true negative in 24/27 benign lesions (specificity: 88.9%) and false positive in 2 hamartomas and in 1 aspecific inflammation (range size: 0.8-2 cm), each with a T/N value </=1.4. Accuracy, positive predictive value and negative predictive value were 91, 96.2 and 77.4%, respectively. Mean T/N value was significantly higher in malignant than in benign nodules (2.1+/-0.6 vs. 1.3+/-0.1, P<0.05), whereas no significant differences were observed between primary lung carcinomas and metastases (2.1+/-0.6 vs. 1.9+/-0.6) or in the different histologic types of carcinomas. 99mTc-tetrofosmin SPECT proved a highly sensitive imaging method in both primary and secondary malignant </=3 cm SPNs detection, with a high accuracy value in discriminating malignant from benign lesions, also by adding semiquantitative analysis. A larger clinical application of this non-invasive, simple and widely available procedure is thus suggested in SPN management, especially when FDG-PET is not available.

PubMed Disclaimer

Substances

LinkOut - more resources