Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2007 Jan 15;109(2):546-51.
doi: 10.1182/blood-2006-04-017988. Epub 2006 Sep 21.

A randomized comparison of bypassing agents in hemophilia complicated by an inhibitor: the FEIBA NovoSeven Comparative (FENOC) Study

Affiliations
Free article
Randomized Controlled Trial

A randomized comparison of bypassing agents in hemophilia complicated by an inhibitor: the FEIBA NovoSeven Comparative (FENOC) Study

Jan Astermark et al. Blood. .
Free article

Abstract

The development of inhibitory antibodies to factor VIII is a serious complication of hemophilia. FEIBA (factor VIII inhibitor-bypassing activity), an activated prothrombin complex concentrate (aPCC), and NovoSeven, recombinant factor VIIa (rFVIIa), are used as hemostatic bypassing agents in treating patients with inhibitors. The FENOC study was designed to test equivalence of the products in the treatment of ankle, knee, and elbow joint bleeding. A prospective, open-label, randomized, crossover, equivalency design was used. The parameters of interest were the percentage of patients who reported efficacy in response to FEIBA and the percentage that reported efficacy in response to NovoSeven. A difference in these percentages of no more than 15% was determined to be a clinically acceptable magnitude for equivalence of the 2 products. The primary outcome was evaluation 6 hours after treatment. Data for 96 bleeding episodes contributed by 48 participants were analyzed. The criterion for declaring the 2 products equivalent at 6 hours was not met; however, the confidence interval of the difference in percentages of efficacy reported for each product only slightly exceeded the 15% boundary (-11.4%-15.7%), P=.059. FEIBA and NovoSeven appear to exhibit a similar effect on joint bleeds, although the efficacy between products is rated differently by a substantial proportion of patients. This trial was registered at www.clinicaltrials.gov as #NCT00166309.

PubMed Disclaimer

Publication types

MeSH terms

Associated data