Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2006 Oct 20;316(1-2):1-7.
doi: 10.1016/j.jim.2006.03.019. Epub 2006 Aug 23.

Protein microarray platform for the multiplex analysis of biomarkers in human sera

Affiliations
Comparative Study

Protein microarray platform for the multiplex analysis of biomarkers in human sera

Teresa Urbanowska et al. J Immunol Methods. .

Abstract

Many biomarkers are currently used to monitor patients in clinical studies. Technologies which evaluate, validate and monitor biomarkers in a cost effective and efficient manner are a necessity. Here we describe the development, validation and implementation of a protein microarray platform for the quantitative and simultaneous analysis of six proteins: IL-1beta, IL-1ra, IL-6, IL-8, MCP-1 and TNFalpha. The platform utilizes a 96-well plate as a solid support on which antibodies are immobilized using non-contact piezoelectric printing. The reaction is based on a sandwich ELISA and the signal is quantified by chemiluminescence with a CCD camera. The robustness and reproducibility of the methodology was investigated using the Food and Drug Administration (FDA) regulatory guidelines for pharmacokinetic assay validation, in which a spike-recovery validation test was elaborated and run over 3 days. The method was shown to be both quantitative and reproducible, with assay accuracy between 70% and 130%, and an assay precision of less than 30%. In addition, protein microarray performance was compared with the classical ELISA approach. Sera collected from a total of 78 individuals were assayed using both approaches. Correlation coefficients (R2) between the two technologies were calculated for each of the analytes: 0.90 for IL-1beta, 0.60 for IL-1ra, 0.93 for IL-6, 0.96 for IL-8, 0.94 for MCP-1 and 0.95 for TNFalpha. The results obtained demonstrate the applicability of this protein microarray for quantitative and simultaneous analysis of IL-1beta, IL-1ra, IL-6, IL-8, MCP-1 and TNFalpha in clinical samples.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources